OSHA SearchOSHA records by employer

Silverstone Electric Company, Inc.: OSHA inspections and violations

Bridgeport, Connecticut · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
9citation items
$3,500current penalties
Jan 18, 2017last inspection

OSHA has inspected Silverstone Electric Company, Inc. 4 times in Connecticut since 1977.

The latest one began on Jan 18, 2017 on a referral, in Bridgeport.

Those inspections ended with 9 citation items: 1 serious and 8 other-than-serious.

Penalties were first proposed at $5,070 and now stand at $3,500, 31% lower after settlements or reviews.

COVID-19 comes up most often in these citations: 6 items under 1926.58.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Silverstone Electric Company, Inc. averages $3,500 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Silverstone Electric Company, Inc.: OSHA citation items per year, 1977 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

87employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Silverstone Electric Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342050838 OPENED JAN 18, 2017Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jul 5, 2017

350 Fairfield Avenue 7th Floor, Bridgeport, CT 06604 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$5,070$3,500Jun 8, 2017Final

Inspection 102744950 OPENED NOV 13, 1987Closed

Unprogrammed related · Partial · Health · 16 employees at the site · Closed May 16, 1988

762 Garfield Ave, Bridgeport, CT 06606 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 7, 1988Closed
Citation 1, item 2 Other-than-serious$0$0Mar 7, 1988Closed
Citation 1, item 3 Other-than-serious$0$0Mar 7, 1988Closed
Citation 1, item 4 Other-than-serious$0$0Mar 7, 1988Closed
Citation 1, item 5 Other-than-serious$0$0Mar 7, 1988Closed
Citation 1, item 6 Other-than-serious$0$0Mar 7, 1988Closed

Inspection 974832 OPENED DEC 26, 1985Closed

Accident · Partial · Safety · 2 employees at the site · Closed Oct 15, 1986

510 Barnum Avenue, Bridgeport, CT 06608 · OSHA's record · Phone and website on Google Maps

Incident on Dec 23, 1985 (fatal): Electric shock - ground fault in electric motor

AN EMPLOYEE OF AN ELECTRICAL CONTRACTING COMPANY WAS WORKING IN THE CEILING PLEN UM OF AN OFFICE AT A COMMUNITY COLLEGE TO REPLACE DEFECTIVE WIRING TO A MOTOR. H E TEMPORARILY CONNECTED THE NEW CONDUCTORS IN A JUNCTION BOX BUT DID NOT CONNECT THE FLEXIBLE METAL CONDUIT SERVING AS THE EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT. HE CLOSED A DISCONNECT SWITCH TO ENERGIZE THE MOTOR AND RECEIVED A FAT AL ELECTRIC SHOCK. FROZEN TO THE CIRCUIT, HIS BODY WAS RELEASED ONLY WHEN THE PO WER TO THE DISCONNECT SWITCH WAS SHUT OFF. THE NEXT DAY, AN ELECTRICIAN TESTED T HE DUCT ON WHICH THE MOTOR WAS SITTING AND FOUND IT TO BE ENERGIZED. ONE OF THE CIRCUIT CONDUCTORS OF THE MOTOR (PEERLESS, 1/6 HORSEPOWER, 1150 RPM, MODEL P-12, SERIAL NUMBER 906389) HAD FAULTED TO THE MOTOR HOUSING, WHICH WAS SITTING ON TH E DUCT.

No citations from this inspection.

Inspection 10520393 OPENED NOV 22, 1977Closed

Planned · Partial · Health · 14 employees at the site · Closed Apr 5, 1978

899 Main St, Bridgeport, CT 06606 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1001(d)(2)(iva) · Asbestos in general industry
Other-than-serious$0$0Feb 24, 1978Closed
Citation 1, item 2
29 CFR 1910.1001(d)(4)(iiia) · Asbestos in general industry
Other-than-serious$0$0Feb 24, 1978Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1001 · Asbestos in general industry

29 CFR 1910.1001(d)(2)(iva)

(2) Initial monitoring. (i) Each employer who has a workplace or work operation covered by this standard, except as provided for in paragraphs (d)(2)(ii) and (d)(2)(iii) of this section, shall perform initial monitoring of employees who are, or may reasonably be expected to be exposed to airborne concentrations at or above the TWA permissible exposure limit and/or excursion limit.

29 CFR 1910.1001(d)(4)(iiia)

(iii) A physical examination including a chest X-ray and pulmonary function test that includes measurement of the employee's forced vital capacity (FVC) and forced expiratory volume at one second (FEV1).

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.417(b)

(b) Equipment and circuits. Equipment or circuits that are deenergized shall be rendered inoperative and shall have tags attached at all points where such equipment or circuits can be energized.

29 CFR 1926.58 · COVID-19

Other electrical contractors and other wiring installation contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.