OSHA SearchOSHA records by employer

Six Brothers Contractors LLC: OSHA inspections and violations

Union City, New Jersey · Masonry Contractors · NAICS 238140

2inspections
4citation items
$18,395current penalties
Sep 15, 2025last inspection

OSHA has inspected Six Brothers Contractors LLC 2 times in New Jersey since 2019.

The latest one began on Sep 15, 2025 after a complaint, in Wayne.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $19,459 and now stand at $18,395, 5% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Six Brothers Contractors LLC averages $9,198 (2 cited inspections).

Six Brothers Contractors LLC: OSHA citation items per year, 2019 to 2025
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

274employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Six Brothers Contractors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348504689 OPENED SEP 15, 2025Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Apr 27, 2026

1700 Valley Road, Wayne, NJ 07470 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,547$2,483Feb 27, 2026Final

Inspection 343850129 OPENED MAR 13, 2019Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Sep 30, 2025

517-519 7th St, Union City, NJ 07087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,304$5,304Jul 22, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,304$5,304Jul 22, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,304$5,304Jul 22, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.