Inspection 349034082 OPENED JUL 2, 2026Open
5061 New Hartford Road, Owensboro, KY 42303 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Saint Joseph, Kentucky · Roofing Contractors · NAICS 238160
SJL Contracting LLC has 2 OSHA inspections on record in Kentucky, the first in 2025.
OSHA's last visit started on Jul 2, 2026, in Owensboro, and the case has not closed yet.
Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.
OSHA proposed $10,500 in penalties and the amount has not been reduced.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. SJL Contracting LLC averages $10,500 over 1 cited inspection in that time.
Kentucky · latest 90 days of OSHA records
180employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kentucky
Checking a subcontractor, a client or your own company? Watch SJL Contracting LLC and get notified the morning OSHA posts a new citation for it.
Watch this company5061 New Hartford Road, Owensboro, KY 42303 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
1211 Venable Ave, Saint Joseph, KY 42301 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $3,500 | $3,500 | Oct 15, 2025 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $3,500 | $3,500 | Oct 15, 2025 | Final |
| Citation 1, item 3 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $3,500 | $3,500 | Oct 15, 2025 | Final |
| Citation 2, item 1 29 CFR 1926.503(b)(1) · Fall protection training in construction |
Other-than-serious | $0 | $0 | Oct 15, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.416(a)(1)
(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.
29 CFR 1926.501(b)(13)
(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.
Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.