SK Baseball: OSHA inspections and violations

Reno, Nevada · Sports Teams and Clubs · NAICS 711211

1inspections
2citation items
$1,960current penalties
Jun 12, 2017last inspection

SK Baseball has one OSHA inspection on record in Nevada.

OSHA opened it on Jun 12, 2017 on a referral, in Reno.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,800 in penalties. After settlements and reviews the total is $1,960, down 30%.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all arts and recreation employers the median penalty per cited inspection since 2015 is $1,400. SK Baseball averages $1,960 over 1 cited inspection in that time.

SK Baseball: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites SK Baseball again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342399219 OPENED JUN 12, 2017Closed

Referral · Partial · Safety · 25 employees at the site · Closed Sep 26, 2017

250 Evans Avenue, Reno, NV 89501 · Sports Teams and Clubs · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,400$980Aug 15, 2017Final
Citation 1, item 2
29 CFR 1910.305(e)(1) · Electrical wiring methods
Serious$1,400$980Aug 15, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(e)(1)

(e) Enclosures for damp or wet locations—(1) Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations.