OSHA SearchOSHA records by employer

Skyler Design Build: OSHA inspections and violations

Fort Campbell, Kentucky · Commercial and Institutional Building Construction · NAICS 236220

1inspections
3citation items
$465current penalties
Sep 26, 2022last inspection

Skyler Design Build has one OSHA inspection on record in Kentucky.

OSHA opened it on Sep 26, 2022, in Fort Campbell.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA proposed $465 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.416, electrical safety in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Skyler Design Build averages $465 over 1 cited inspection in that time.

Skyler Design Build: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

180employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Skyler Design Build and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346246622 OPENED SEP 26, 2022Closed

Unprogrammed other · Partial · Safety · 21 employees at the site · Closed Feb 2, 2023

Bldg 3713 1st Bct Volar Barracks, Fort Campbell, KY 42223 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Other-than-serious$465$465Jan 5, 2023Final
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Other-than-serious$0$0Jan 5, 2023Final
Citation 1, item 3
29 CFR 1926.416(a)(3) · Electrical safety in construction
Other-than-serious$0$0Jan 5, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(x)

(x) Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

Other commercial and institutional building construction employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.