OSHA SearchOSHA records by employer

Sloan Valve Company: OSHA inspections and violations

Andover, Massachusetts · Other Metal Valve and Pipe Fitting Manufacturing · NAICS 332919

1inspections
4citation items
$5,000current penalties
Feb 4, 2020last inspection

OSHA has inspected Sloan Valve Company once in Massachusetts.

The inspection began on Feb 4, 2020 on a referral, in Andover.

That inspection ended with 4 citation items: 1 serious and 3 other-than-serious.

Penalties were first proposed at $19,278 and now stand at $5,000, 74% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Sloan Valve Company averages $5,000 (1 cited inspection).

Sloan Valve Company also files yearly injury logs with OSHA, summarized below.

Sloan Valve Company: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Sloan Valve Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Sloan Valve Company at 4 sites in 2 states. Together they've had 21 inspections and $201,118 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 344606132 OPENED FEB 4, 2020Closed

Referral · Partial · Safety · 70 employees at the site · Closed Sep 30, 2020

19 Connector Road Unit 4, Andover, MA 01810 · Other Metal Valve and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 3, 2020: Employee crushes finger when caught in jammed pneumatic pres

At 4:30 p.m. on February 3, 2020, an employee working as a mechanical assembler for a pipe and valve manufacturer was working in the area of the Crimper 2 Pneumatic Press. The press was being operated by a coworker who is also a mechanical assembler. The employee routinely operates the press, and the crew was working overtime in an attempt to satisfy a deadline. The press jammed and the coworker was unable to clear the machine. The employee attempted to unjam the machine by forcibly moving the cylinder of the crimper down to the home position. The employee was able to move the cylinder, but it slipped from her grip before arriving at the home position. As a result, she caught her left index finger in the point of operation. The employee was stuck and unable to be extricated from the press for approximately 30 minutes. Once she was freed, the employee was transported to the hospital and subsequently transferred to a medical center via ambulance. The employee crushed her left index finger and required surgery to repair the tendons and bone. The employee did not require amputation as the result of this incident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$9,639$2,500Mar 18, 2020Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 18, 2020Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Mar 18, 2020Final
Citation 1, item 2
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$9,639$2,500Mar 18, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Andover site logged 0 recordable injuries or illnesses among about 85 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Sloan Valve Company-Andover
Andover · 2025
85 000.02.4
Sloan Valve Company- Andover
Andover · 2019
111 000.02.4
Sloan - Andover
Andover · 2018
97 000.02.4

Included with any plan: 2 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.147(c)(7)(iv)

(iv) The employer shall certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training.

Other other metal valve and pipe fitting manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.