OSHA SearchOSHA records by employer

SM Roofing and Siding: OSHA inspections and violations

Bridgeton, New Jersey · Roofing Contractors · NAICS 238160

2inspections
7citation items
$28,672current penalties
Nov 3, 2021last inspection

SM Roofing and Siding has 2 OSHA inspections on record in New Jersey, the first in 2020.

OSHA's last visit started on Nov 3, 2021 to follow up on an earlier case, in Oceanport.

Across those inspections OSHA issued 7 citation items: 7 serious.

OSHA proposed $28,672 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. SM Roofing and Siding averages $28,672 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

SM Roofing and Siding: OSHA citation items per year, 2020 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

39 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch SM Roofing and Siding and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345615561 OPENED NOV 3, 2021Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Dec 10, 2021

449 Branchport Ave, Oceanport, NJ 07757 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345052377 OPENED DEC 7, 2020Closed

Fatality or catastrophe · Complete · Safety · 5 employees at the site · Closed Aug 5, 2026

207 20th Street S, Bridgeton, NJ 08302 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Dec 6, 2020 (fatal): One employee is electrocuted, one is injured while moving sc

At 5:45 p.m. on December 6, 2020, Employees #1 and #2 and coworkers, employed by a roofing and siding company, were working at the construction site of a new two-story residence. Employees #1 and #2 were repositioning a pump jack scaffold from the back of the house to another location. According to a coworker who witnessed the event, the two employees were in the process of laying down parallel to the house a 36-foot Alum-A-Pole, part of the scaffold system, when they appeared to lose control of the pole as a gust of wind came around the house's corner. The pole toppled onto energized overhead power lines 8 to 10 feet away, and electrical current flowed through the pole to the employees. Employee #1 was electrocuted. Employee #2 was transported to the hospital for treatment of electric shock injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 4
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 5
29 CFR 1926.454(a)(2) · Scaffold training
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 6
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,096$4,096Jun 3, 2021Final
Citation 1, item 7
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,096$4,096Jun 3, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.