OSHA SearchOSHA records by employer

Smart Remodeling & Restoration LLC: OSHA inspections and violations

Colorado Springs, Colorado · Residential Remodelers · NAICS 236118

1inspections
3citation items
$2,926current penalties
Mar 26, 2021last inspection

OSHA inspectors have visited Smart Remodeling & Restoration LLC in Colorado one time.

It opened on Mar 26, 2021 as a planned inspection, in Colorado Springs.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $2,926 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Smart Remodeling & Restoration LLC averages $2,926 across 1 cited inspection.

Smart Remodeling & Restoration LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Smart Remodeling & Restoration LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345236848 OPENED MAR 26, 2021Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 12, 2023

5010 N. Academy Blvd., Colorado Springs, CO 80918 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,926$2,926Apr 20, 2021Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Apr 20, 2021Final
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Apr 20, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.