OSHA SearchOSHA records by employer

Smiley Siding & Roofing, Inc.: OSHA inspections and violations

Peachtree City, Georgia · Siding Contractors · NAICS 238170

3inspections
11citation items
$44,956current penalties
May 17, 2021last inspection

Smiley Siding & Roofing, Inc. has 3 OSHA inspections on record in Georgia, the first in 2018.

OSHA's last visit started on May 17, 2021 as a planned inspection, in Peachtree City.

Across those inspections OSHA issued 11 citation items: 7 serious, 2 repeat and 2 other-than-serious.

OSHA proposed $44,956 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Smiley Siding & Roofing, Inc. averages $14,985 over 3 cited inspections in that time.

Smiley Siding & Roofing, Inc.: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Smiley Siding & Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345312110 OPENED MAY 17, 2021Closed

Planned · Partial · Safety · 11 employees at the site · Closed Jan 6, 2026

(lot #373) 814 Parker Pass, Peachtree City, GA 30269 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(k)(3) · Rules for each type of scaffold
Serious$4,291$4,291Jul 16, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,149$5,149Jul 16, 2021Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Repeat$12,015$12,015Jul 16, 2021Final
Citation 2, item 2
29 CFR 1926.1153(c)(1) · Silica dust in construction
Repeat$8,583$8,583Jul 16, 2021Final

Inspection 344707336 OPENED MAR 19, 2020Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jul 8, 2022

Lot #347 Palmer Street, Peachtree City, GA 30269 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,313$2,313Apr 20, 2020Final
Citation 1, item 2
29 CFR 1926.304(d) · Woodworking tools
Serious$2,892$2,892Apr 20, 2020Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,049$4,049Apr 20, 2020Final
Citation 1, item 4
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$2,892$2,892Apr 20, 2020Final
Citation 2, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$0$0Apr 20, 2020Final

Inspection 343366233 OPENED AUG 7, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 28, 2020

(lot #112) 355 Meeting Street, Marietta, GA 30060 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,772$2,772Sep 6, 2018Final
Citation 2, item 1
29 CFR 1926.454(a)(2) · Scaffold training
Other-than-serious$0$0Sep 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(c)(1)

(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.