Inspection 341762458 OPENED SEP 8, 2016Closed
1455 Hagan Ave, Huger, SC 29450 · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Huger, South Carolina · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · NAICS 334416
OSHA has inspected SMS Elotherm North America 2 times in South Carolina since 2015.
The latest one began on Sep 8, 2016 to follow up on an earlier case, in Huger.
Those inspections ended with 5 citation items: 5 serious.
Penalties were first proposed at $22,500 and now stand at $20,250, 10% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 5 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and SMS Elotherm North America averages $20,250 (1 cited inspection).
1 inspection on this page followed a fatal incident.
South Carolina · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch SMS Elotherm North America and get notified the morning OSHA posts a new citation for it.
Watch this company1455 Hagan Ave, Huger, SC 29450 · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1455 Hagan Ave, Huger, SC 29450 · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jul 25, 2015 (fatal): Employee is killed when caught between heat inductors
At 10:30 a.m. on July 25, 2015, Employee #1 was replacing bus bars inside the cabinet of a Heat Inductor #1 at a host employer. Employee #1 worked for the manufacturer of the equipment and was tasked with maintenance and technical support to host employer. Employee #1 requested assistance from the host employer with lifting a heavy object and the host employer sent a utility technician to assist him. Employee #1 was working with the utility technician at the machine's maintenance position. Heat Inductor #1 was locked out with a host employer maintenance lock for protection of the equipment only. Heat Inductor #1 was in the maintenance position, which was all the way back to the end of the track. Heat inductor #2 was taken offline by the operator. The operator was located in the operator's pulpit and could not see Employee #1 or the utility technician. Each heat inductor cabinet was approximately 157 inches long by 35 inches wide by 90 inches tall. The actual inductor hooked to the cabinet and extended another 10 to 12 feet. Each cabinet had 4 side hinged doors, running down both sides, for a total of 8 doors on the cabinet. The inductors had 3 standard positions: in line for operation; resting or offline position; and maintenance position. Each inductor ran on metal tracks that extended approximately 40 feet to accommodate the 3 positions of the inductors. Both heat inductors were driven at 50 HP when moving on the tracks. As Heat Inductor #2 moved to the resting position, Employee #1 became caught between Heat Inductors #1 and #2. Employee #1 was positioned to the inside of Heat Inductor #1, between inductors #1 and #2. The utility technician was on the outside, not around any other moving inductors or moving equipment. Employee #1 was killed and suffered from total body blunt force trauma resulting from being crushed between Heat Inductors #1 and #2.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $4,500 | $4,500 | Jan 21, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $4,500 | $4,500 | Jan 21, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $4,500 | $4,500 | Jan 21, 2016 | Final |
| Citation 1, item 4a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $4,500 | $2,250 | Jan 21, 2016 | Final |
| Citation 1, item 4b 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $4,500 | $4,500 | Jan 21, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(ii)
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
29 CFR 1910.147(d)(4)(i)
(4) Lockout or tagout device application. (i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.