OSHA SearchOSHA records by employer

Snyder Steel Inc: OSHA inspections and violations

Satellite Beach, Florida · Fabricated Structural Metal Manufacturing · NAICS 332312

3inspections
8citation items
$3,724current penalties
Feb 28, 2024last inspection

Since 1997, OSHA inspectors have visited Snyder Steel Inc in Florida 3 times.

The most recent inspection opened on Feb 28, 2024 as a planned inspection, in Merritt Island.

In all, OSHA issued 8 citation items: 3 serious and 5 other-than-serious.

The penalties, $3,724 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Snyder Steel Inc averages $3,349 across 1 cited inspection.

Snyder Steel Inc: OSHA citation items per year, 1997 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Snyder Steel Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347310666 OPENED FEB 28, 2024Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 22, 2024

608 South Plumosa Street, Merritt Island, FL 32952 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346541741 OPENED FEB 17, 2023Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jan 6, 2026

3031 Hafen Lane, Melbourne, FL 32951 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,349$3,349Aug 16, 2023Final

Inspection 109315754 OPENED JUL 1, 1997Closed

Complaint · Complete · Safety · 3 employees at the site · Closed Aug 8, 1997

1175 N. Hwy A1a, Satellite Beach, FL 32937 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.454(a) · Scaffold training
Serious$375$375Jul 17, 1997Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 17, 1997Closed
Citation 2, item 1
29 CFR 1926.451(d)(3)(x) · Scaffolds, general requirements
Other-than-serious$0$0Jul 17, 1997Closed
Citation 2, item 2
29 CFR 1926.451(f)(17)(i) · Scaffolds, general requirements
Other-than-serious$0$0Jul 17, 1997Closed
Citation 2, item 3
29 CFR 1926.451(f)(17)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Jul 17, 1997Closed
Citation 2, item 4
29 CFR 1926.451(f)(17)(iii) · Scaffolds, general requirements
Other-than-serious$0$0Jul 17, 1997Closed
Citation 2, item 5
29 CFR 1926.451(f)(17)(iv) · Scaffolds, general requirements
Other-than-serious$0$0Jul 17, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(3)(x)

(x) Tiebacks shall be installed perpendicular to the face of the building or structure, or opposing angle tiebacks shall be installed. Single tiebacks installed at an angle are prohibited.

29 CFR 1926.451(f)(17)(i)

(i) An insulated thimble shall be used to attach each suspension wire rope to its hanging support (such as cornice hook or outrigger). Excess suspension wire rope and any additional independent lines from grounding shall be insulated;

29 CFR 1926.451(f)(17)(ii)

(ii) The suspension wire rope shall be covered with insulating material extending at least 4 feet (1.2 m) above the hoist. If there is a tail line below the hoist, it shall be insulated to prevent contact with the platform. The portion of the tail line that hangs free below the scaffold shall be guided or retained, or both, so that it does not become grounded;

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.503 · Fall protection training in construction

Other fabricated structural metal manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.