OSHA SearchOSHA records by employer

Solar Help Hawaii LLC: OSHA inspections and violations

Honolulu, Hawaii · Solar Electric Power Generation · NAICS 221114

3inspections
7citation items
$2,182current penalties
Aug 11, 2015last inspection

OSHA has inspected Solar Help Hawaii LLC 3 times in Hawaii since 2010.

The latest one began on Aug 11, 2015 as part of a related case, in Honolulu.

Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $3,225 and now stand at $2,182, 32% lower after settlements or reviews.

Fall protection training in construction comes up most often in these citations: 4 items under 1926.503.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Solar Help Hawaii LLC averages $1,470 (1 cited inspection).

Solar Help Hawaii LLC: OSHA citation items per year, 2010 to 2015
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

63employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Solar Help Hawaii LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340849728 OPENED AUG 11, 2015Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Oct 30, 2015

924 Hausten St, Honolulu, HI 96826 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$1,050$735Sep 22, 2015Final
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$1,050$735Sep 22, 2015Final
Citation 2, item 1
29 CFR 12-110-3(C)
Other-than-serious$0$0Sep 22, 2015Final

Inspection 340862275 OPENED AUG 10, 2015Closed

Complaint · No inspection · Safety · 3 employees at the site · Closed Aug 10, 2015

47-754 Hui Ulili St, Kaneohe, HI 96744 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313079345 OPENED APR 21, 2010Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 4, 2010

2917 Loomis St, Honolulu, HI 96822 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$375$238Jun 9, 2010Closed
Citation 1, item 2a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$375$238Jun 9, 2010Closed
Citation 1, item 2b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Jun 9, 2010Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$238Jun 9, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(a)(1)

(a) Training program. (1) The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.

Other solar electric power generation employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.