OSHA SearchOSHA records by employer

Sonray Solar: OSHA inspections and violations

Reno, Nevada · Roofing Contractors · NAICS 238160

4inspections
4citation items
$7,581current penalties
May 1, 2025last inspection

Sonray Solar has 4 OSHA inspections on record in Nevada, the first in 2019.

OSHA's last visit started on May 1, 2025, in Reno.

Across those inspections OSHA issued 4 citation items: 2 serious, 1 repeat and 1 other-than-serious.

OSHA proposed $14,616 in penalties. After settlements and reviews the total is $7,581, down 48%.

Most often, OSHA cited 1926.102, eye and face protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Sonray Solar averages $2,527 over 3 cited inspections in that time.

Sonray Solar: OSHA citation items per year, 2019 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Sonray Solar again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348218058 OPENED MAY 1, 2025Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Dec 30, 2025

4006 Copper Cove Ct, Reno, NV 89511 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$7,035$3,518Aug 15, 2025Final
Citation 1, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$7,035$3,518Aug 15, 2025Final

Inspection 347609752 OPENED JUL 11, 2024Closed

Unprogrammed related · Partial · Health · 48 employees at the site · Closed Jul 31, 2024

1433 Ivory Sage Drive, Reno, NV 89521 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345222723 OPENED MAR 24, 2021Closed

Referral · Partial · Safety · 2 employees at the site · Closed Oct 4, 2021

8962 Sagemoor Dr., Reno, NV 89506 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$546$546Aug 20, 2021Final

Inspection 343872396 OPENED MAR 22, 2019Closed

Referral · Partial · Safety · 5 employees at the site · Closed Oct 16, 2019

600 Geiger Grade Road, Reno, NV 89521 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Jun 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other roofing contractors employers in Nevada

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.