OSHA SearchOSHA records by employer

South Central Stucco Company, LLC: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

1inspections
4citation items
$5,100current penalties
Feb 15, 2018last inspection

OSHA has inspected South Central Stucco Company, LLC once in Texas.

The inspection began on Feb 15, 2018 as a planned inspection, in San Antonio.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $12,749 and now stand at $5,100, 60% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and South Central Stucco Company, LLC averages $5,100 (1 cited inspection).

South Central Stucco Company, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

404employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch South Central Stucco Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342955127 OPENED FEB 15, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 12, 2022

1807 N. Loop 1604 E., San Antonio, TX 78259 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$2,217$1,000Apr 11, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,880$1,550Apr 11, 2018Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(iv) · Scaffolds, general requirements
Serious$2,772$1,000Apr 11, 2018Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$3,880$1,550Apr 11, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(iv)

(iv) Each employee on a self-contained adjustable scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) when the platform is supported by the frame structure, and by both a personal fall arrest system and a guardrail system (with minimum 200 pound toprail capacity) when the platform is supported by ropes;

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.