OSHA SearchOSHA records by employer

South County Construction Company: OSHA inspections and violations

Washington, District of Columbia · Masonry Contractors · NAICS 238140

10inspections
27citation items
$38,070current penalties
Apr 3, 2018last inspection

OSHA has inspected South County Construction Company 10 times in District of Columbia since 1995.

The latest one began on Apr 3, 2018 as a planned inspection, in Washington.

Those inspections ended with 27 citation items: 20 serious, 6 repeat and 1 other-than-serious.

Penalties were first proposed at $54,684 and now stand at $38,070, 30% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 17 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and South County Construction Company averages $6,500 (1 cited inspection).

South County Construction Company: OSHA citation items per year, 1995 to 2018
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch South County Construction Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343071700 OPENED APR 3, 2018Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 30, 2019

1250 Taylor St., Nw, Washington, DC 20006 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$6,047$3,600Jul 16, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jul 16, 2018Final
Citation 1, item 1c
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Jul 16, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,837$2,900Jul 16, 2018Final

Inspection 312331788 OPENED AUG 4, 2008Closed

Referral · Complete · Safety · 6 employees at the site · Closed Nov 21, 2008

1618 Bladensburg Road, Ne, Washington, DC 20017 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$4,200$2,520Sep 3, 2008Closed

Inspection 309389971 OPENED OCT 26, 2005Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jul 17, 2006

1400 Church Street Nw, Washington, DC 20005 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,125$600Nov 1, 2005Closed

Inspection 309249274 OPENED AUG 22, 2005Closed

Unprogrammed related · Complete · Safety · 15 employees at the site · Closed Jun 6, 2008

1400 Church Street, Nw, Washington, DC 20005 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$900$0Sep 2, 2005Closed
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$15,000$10,000Sep 2, 2005Closed

Inspection 308268192 OPENED NOV 19, 2004Closed

Referral · Complete · Safety · 19 employees at the site · Closed Aug 9, 2005

800 Potomac Ave, Sw, Washington, DC 20024 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$6,000$4,000Nov 29, 2004Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$6,000$4,000Nov 29, 2004Closed

Inspection 306696667 OPENED AUG 18, 2004Closed

Referral · Complete · Safety · 13 employees at the site · Closed Oct 4, 2004

5233 North Capital St. Ne, Washington, DC 20011 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$3,000Aug 26, 2004Closed
Citation 1, item 3b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Aug 26, 2004Closed

Inspection 304759210 OPENED JUN 27, 2002Closed

Unprogrammed other · Complete · Safety · 9 employees at the site · Closed Jul 29, 2002

916 G Street, N.w., Washington, DC 20001 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.250(b)(7) · General requirements for storage
Other-than-serious$500$0Jul 5, 2002Closed
Citation 1, item 3a
29 CFR 1926.307(d)(1) · Mechanical power-transmission apparatus
Serious$500$500Jul 5, 2002Closed
Citation 1, item 3b
29 CFR 1926.307(e)(1)(i) · Mechanical power-transmission apparatus
Serious$0$0Jul 5, 2002Closed
Citation 1, item 3c
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$0$0Jul 5, 2002Closed

Inspection 301100277 OPENED OCT 17, 1997Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Dec 2, 1997

4200 Harewood Road, N.e., Washington, DC 20017 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$375$375Oct 23, 1997Closed
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$500$375Oct 23, 1997Closed
2 older inspections

Inspection 123518482 OPENED JAN 17, 1997Closed

Planned · Complete · Safety · 18 employees at the site · Closed Apr 15, 1997

4125 Albemarle St., N.w., Washington, DC 20016 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Repeat$2,400$2,400Jan 31, 1997Contested
Citation 1, item 4
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Repeat$4,200$2,400Jan 31, 1997Contested

Inspection 117943316 OPENED FEB 17, 1995Closed

Planned · Complete · Safety · 15 employees at the site · Closed May 10, 1995

4601 M.l.k. Blvd., Sw, Washington, DC 20032 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$525$350Mar 6, 1995Closed
Citation 1, item 2a
29 CFR 1926.451(a)(3) · Scaffolds, general requirements
Serious$525$350Mar 6, 1995Closed
Citation 1, item 2b
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0Mar 6, 1995Closed
Citation 1, item 3a
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Serious$525$350Mar 6, 1995Closed
Citation 1, item 3b
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Serious$0$0Mar 6, 1995Closed
Citation 1, item 3c
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Serious$0$0Mar 6, 1995Closed
Citation 1, item 4
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$525$350Mar 6, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.250(b)(7)

(7) When masonry blocks are stacked higher than 6 feet, the stack shall be tapered back one-half block per tier above the 6-foot level.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.