OSHA SearchOSHA records by employer

South County Contractors Inc.: OSHA inspections and violations

Washington, District of Columbia · Masonry Contractors · NAICS 238140

2inspections
4citation items
$9,360current penalties
Mar 31, 2016last inspection

South County Contractors Inc. has 2 OSHA inspections on record in District of Columbia, the first in 2008.

OSHA's last visit started on Mar 31, 2016 as a planned inspection, in Washington.

Across those inspections OSHA issued 4 citation items: 4 serious.

OSHA proposed $14,400 in penalties. After settlements and reviews the total is $9,360, down 35%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. South County Contractors Inc. averages $7,560 over 1 cited inspection in that time.

South County Contractors Inc.: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch South County Contractors Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341366151 OPENED MAR 31, 2016Closed

Planned · Complete · Safety · 110 employees at the site · Closed Sep 13, 2017

1400 Rhode Island Ave. Ne, Washington, DC 20018 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$6,300$3,780May 26, 2016Final
Citation 1, item 2
29 CFR 1926.602(c)(1)(viii)(a) · Earthmovers and forklifts in construction
Serious$6,300$3,780May 26, 2016Final

Inspection 311897623 OPENED MAR 20, 2008Closed

Referral · Complete · Safety · 11 employees at the site · Closed Aug 11, 2008

1618 Bladensburg Road Ne, Washington, DC 20002 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$900$900Apr 4, 2008Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$900$900Apr 4, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other masonry contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.