OSHA SearchOSHA records by employer

Southeast Roofing & Construction, Inc.: OSHA inspections and violations

Pensacola, Florida · Roofing Contractors · NAICS 238160

2inspections
3citation items
$9,442current penalties
Mar 31, 2022last inspection

Since 2012, OSHA inspectors have visited Southeast Roofing & Construction, Inc. in Florida 2 times.

The most recent inspection opened on Mar 31, 2022 as a planned inspection, in Daytona Beach.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $18,355; today they stand at $9,442, 49% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Southeast Roofing & Construction, Inc. averages $8,158 across 1 cited inspection.

Southeast Roofing & Construction, Inc. also files yearly injury logs with OSHA, summarized below.

Southeast Roofing & Construction, Inc.: OSHA citation items per year, 2012 to 2022
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Southeast Roofing & Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345870646 OPENED MAR 31, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 18, 2023

1635 North Williamson Blvd, Daytona Beach, FL 32117 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$6,164$3,082May 24, 2022Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$10,151$5,076May 24, 2022Final

Inspection 337649420 OPENED NOV 28, 2012Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 15, 2013

8792 Spider Lily Way, Pensacola, FL 32526 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,040$1,285Jan 28, 2013Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Pensacola site logged 0 recordable injuries or illnesses among about 23 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Southeast Roofing & Construction Inc
Pensacola · 2022
23 000.02.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.