OSHA SearchOSHA records by employer

Southeastern Erectors, Inc: OSHA inspections and violations

Biloxi, Mississippi · Structural Steel and Precast Concrete Contractors · NAICS 238120

7inspections
13citation items
$16,768current penalties
Oct 3, 2024last inspection

Since 1996, OSHA inspectors have visited Southeastern Erectors, Inc in Mississippi 7 times.

The most recent inspection opened on Oct 3, 2024 as a planned inspection, in Biloxi.

In all, OSHA issued 13 citation items: 11 serious and 2 other-than-serious.

The proposed penalties came to $25,994; today they stand at $16,768, 35% less.

The rule cited most here is 1926.760 (fall protection), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Southeastern Erectors, Inc averages $5,268 across 1 cited inspection.

Southeastern Erectors, Inc: OSHA citation items per year, 1996 to 2024
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

15employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Southeastern Erectors, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347793499 OPENED OCT 3, 2024Closed

Planned · Partial · Safety · 6 employees at the site · Closed Nov 22, 2024

Next To 8701 Tucker Rd., Biloxi, MS 39530 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$5,323$3,194Oct 24, 2024Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,457$2,074Oct 24, 2024Final

Inspection 344364443 OPENED OCT 8, 2019Closed

Planned · Partial · Safety · 9 employees at the site · Closed Oct 9, 2019

Robinson Rd. & Canal Rd., Gulfport, MS 39503 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315306241 OPENED DEC 13, 2011Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 27, 2012

695 Beach Blvd, Biloxi, MS 39530 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,805$1,400Jan 13, 2012Closed
Citation 1, item 2a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,384$1,200Jan 13, 2012Closed
Citation 1, item 2b Serious$0$0Jan 13, 2012Closed
Citation 1, item 3
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,805$1,400Jan 13, 2012Closed

Inspection 313635930 OPENED FEB 9, 2011Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 6, 2011

Waveland Municiple Complex, Coleman Ave., Waveland, MS 39576 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,620$2,900Feb 22, 2011Closed
Citation 1, item 2
29 CFR 1926.760(b)(3) · Fall protection
Other-than-serious$0$0Feb 22, 2011Closed

Inspection 311414692 OPENED MAY 20, 2008Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jun 26, 2008

3295 Warrior Dr, D'iberville, MS 39540 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$800$800Jun 19, 2008Closed
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,000$2,000Jun 19, 2008Closed

Inspection 304313455 OPENED MAR 22, 2002Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 9, 2002

1021 Popps Ferry Road, Biloxi, MS 39530 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$1,500Apr 1, 2002Closed

Inspection 107093742 OPENED JUN 4, 1996Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 19, 1996

Range 45,camp Shelby, Hattiesburg, MS 39402 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(c)(1)(viiia) · Earthmovers and forklifts in construction
Serious$300$300Jul 2, 1996Closed
Citation 2, item 1
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Other-than-serious$0$0Jul 1, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iii)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.