OSHA SearchOSHA records by employer

Southern Brick, LLC: OSHA inspections and violations

Richmond, Virginia · Masonry Contractors · NAICS 238140

8inspections
12citation items
$6,238current penalties
Dec 4, 2025last inspection

Since 1989, OSHA inspectors have visited Southern Brick, LLC in Virginia 8 times.

The most recent inspection opened on Dec 4, 2025, in Midlothian.

In all, OSHA issued 12 citation items: 8 serious and 4 other-than-serious.

The proposed penalties came to $9,165; today they stand at $6,238, 32% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Southern Brick, LLC averages $1,484 across 4 cited inspections.

Southern Brick, LLC: OSHA citation items per year, 1989 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Southern Brick, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348624412 OPENED DEC 4, 2025Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Mar 19, 2026

13030 Genito Road, Midlothian, VA 23112 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Feb 10, 2026Final

Inspection 346932387 OPENED AUG 22, 2023Closed

Planned · Complete · Safety · 8 employees at the site · Closed Oct 30, 2023

2825 Dock St, Richmond, VA 23223 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,075$3,075Sep 15, 2023Final
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Sep 15, 2023Final
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 15, 2023Final

Inspection 345412159 OPENED JUL 12, 2021Closed

Referral · Complete · Safety · 38 employees at the site · Closed Jul 19, 2021

13900 Midlothian Turnpike, Midlothian, VA 23113 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344355359 OPENED OCT 3, 2019Closed

Planned · Complete · Safety · 50 employees at the site · Closed Oct 16, 2019

2119 Stockton Street, Richmond, VA 23224 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343925996 OPENED APR 11, 2019Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Jun 25, 2019

12500 Haley Club Dr., Ashland, VA 23005 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$1,235$864Jun 13, 2019Final
Citation 1, item 2
29 CFR 1926.1153(d)(2)(i) · Silica dust in construction
Serious$1,620$1,134Jun 13, 2019Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Jun 13, 2019Final

Inspection 343787016 OPENED FEB 14, 2019Open

Planned · Partial · Safety · 6 employees at the site · Open

11049 West Broad Street, Glen Allen, VA 23060 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 343787537 OPENED FEB 14, 2019Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 5, 2019

11049 West Broad Street, Glen Allen, VA 23060 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,235$864Mar 20, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 20, 2019Final

Inspection 105732705 OPENED JUN 29, 1989Closed

Planned · Complete · Safety · 13 employees at the site · Closed Oct 25, 1991

4650 Oakley Lane, Richmond, VA 23230 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$2,000$300Aug 11, 1989Final
Citation 2, item 4
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Aug 11, 1989Final
Citation 2, item 5
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Other-than-serious$0$0Aug 11, 1989Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(d)(2)(i)

(2) Exposure assessment—(i) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.451 · Scaffolds, general requirements

Other masonry contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.