Inspection 349273490 OPENED NOV 9, 2026Open
8810 Mission Gorge Road, Santee, CA 92071 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
San Diego, California · All Other Outpatient Care Centers · NAICS 621498
Since 1989, OSHA inspectors have visited Southern Contracting Company in California 9 times.
The most recent inspection opened on Nov 9, 2026 as part of a related case, in Santee and is still open.
In all, OSHA issued 5 citation items: 1 serious and 4 other-than-serious.
The proposed penalties came to $41,210; today they stand at $24,710, 40% less.
Among health care employers, the typical cited inspection since 2015 ends with a $1,050 penalty. Southern Contracting Company averages $18,000 across 1 cited inspection.
1 inspection on this page followed a fatal incident.
California · latest 90 days of OSHA records
1,111employers cited
Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in California
Checking a subcontractor, a client or your own company? Watch Southern Contracting Company and get notified the morning OSHA posts a new citation for it.
Watch this company8810 Mission Gorge Road, Santee, CA 92071 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
4182 Quapaw Ave, San Diego, CA 92117 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
Incident on Aug 1, 2018: Employee incurs multiple injuries when struck by excavator b
At 3:15 p.m. on August 1, 2018, an employee was working with two coworkers to excavate a trench using an excavator (Caterpillar 305E CR) with a twelve inch excavator bucket along with a rotary hammer, a jack hammer and shovels to lay communication cables. At some point, coworker #1, operating the excavator, shut off the excavator to go talk with the foreman. Meanwhile, the employee, who also acted as coworker #1's spotter, entered the deepest part of the trench (ten feet long by two feet wide and four feet, eight inches deep) to hand dig under the two foot wall that sat at grade above him. Coworker #2 was in another section using a jackhammer to loosen soil and was faced away from the employee. Coworker #1 returned to the excavator and started it up and began to dig in the same spot in the trench where the employee was working. The excavator bucket struck the employee, who was hospitalized for crushing injuries that include: fractures to lumbar vertebra with spinal cord injury, fractures to left arm and leg, fractured ribs, acute head trauma, and multiple contusions. contusions.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1592(E) |
Serious | $18,000 | $18,000 | Nov 9, 2018 | Final |
3201 Wheeler Ave, La Verne, CA 91750 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Aug 2, 2011: Employee falls from elevated platform
On August 2, 2011, electrical equipment was being installed to service the chemi cal tank farm for the "Orion" project by the company. Employee #1 planned to ele ctrically bond the metal cable trays to electrical conduits nearby. At approxima tely 8:45 a.m., Employee #1 had just finished gathering and bringing his tools a nd equipment to the elevated cable tray when he fell twenty one feet to the conc rete ground below. Employee #2 saw Employee #1 fall from the top most cable tray and hitting his head on a fiberglass railing as he fell to the ground. Employee #1 suffered a fractured rib, a fractured wrist, a laceration to the head, among st other injuries and was transported via helicopter to LAC/USC Medical Center w here he stayed for approximately 30 hours for treatment to his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1629 C03 |
Other-than-serious | $335 | $335 | Feb 2, 2012 | Final |
| Citation 2, item 1 29 CFR 1670 A |
Other-than-serious | $22,500 | $6,000 | Feb 2, 2012 | Final |
Military Housing Nave Amph. Base, San Diego, CA 92135 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.28(a) · Personal protective equipment |
Other-than-serious | $375 | $375 | Jan 24, 2007 | Final |
Mtn View Rd /stone Ridge Rd, San Diego, CA 92021 · All Other Outpatient Care Centers · OSHA's record · Phone and website on Google Maps
Incident on Nov 18, 2003: Employee injured in fall from power pole
At 1:45 p.m. on November 18, 2003, Employee #1 was part of a crew replacing powe r poles that had been destroyed by fire in a remote part of Harbison Canyon, CA. At the time of the accident, he was setting up the electrical equipment on the new poles. Employee #1 was hanging a hand line on an arm gin for new power lines when he shifted his weight and leaned back. His safety clip detached from the D -ring on his safety harness and he fell approximately 35 ft onto the duff on the ground, and then tumbled downhill. The foreman was about 5 ft away from the pol e and he contacted the general manager, who call the paramedics. Employee #1 sus tained three fractured vertebrae, a dislocated leg, a separated kidney, a right rotator cuff injury, and fractured ribs. He was flown to Sharp Memorial Hospital in San Diego, CA, where he was admited to intensive care. The employer had prov ided proper training and instruction on safety practices related to high voltage electrical work in remore and elevated locations. The employer had also provide d fall protection and other appropriate equipment for the job. Employee #1's saf ety clip had became wedged between the V-brace and the cross arm brace at the to p of the pole, causing it to become unclipped.
No citations from this inspection.
22212 Brookhurst St, Huntington Beach, CA 92649 · OSHA's record · Phone and website on Google Maps
Incident on Aug 6, 2002 (fatal): One killed, four injured in electrical explosion
At 7:40 a.m. on August 6, 2002, Employees #1 through #4, all subcontract electri ans, were preparing to remove and replace a 12-kilovolt electrical bus at a publ ic sanitation waste water treatment facility. Employee #1, a journeyman electric ian and also the foreman, opened the circuit leading to the bus being removed, a nd locked out that system with two locks. He then instructed Employee #2 to open the back of the equipment so that they could get at the bus. Employees #1 throu gh #3 together opened the compartment, after which Employees #2 and #3 left the area to get additional equipment. Upon their return, they observed that Employee #1 had already attached one end of a grounding strap to the cabinet. When the o ther end of the grounding strap contacted the 12-kilovolt circuit, there was an electrical explosion and fire ball. Seconds later, as the public electrical util ity system tried to come back on line, a second explosion and fire ball occurred . Employee #1 was directly in front of both explosions and suffered third-degree burns over 90 percent of his body; he was transported to the hospital, where he died 23 days later. Employees #2 and #3, who had been watching the attachment o f the grounding strap, were hospitalized with second- and third-degree burns to their faces and arms. Employee #4 and Employee #5, the safety inspector for the general contractor, were also observing the process and received minor singeing and contusions, for which they were treated and released that same day. Subseque nt investigation revealed that Employee #1 apparently told Employee #2 the wrong compartment number to open so they were actually working on energized lines. Em ployee #1 had available a SB Touch Tester, serial #10493, which Employees #1 and #3 had checked was operating before entering the building. Employee #4 stated E mployee #1 had not used it before attaching the grounding strap. After the accid ent, the tester was checked at a lab and found to be functioning properly.
No citations from this inspection.
Pier 4, Naval Station, San Diego, CA 92136 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5001 Chino Hills Pkwy, Chino, CA 91710 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1509 C |
Other-than-serious | $0 | $0 | Mar 28, 1991 | Closed |
26801 Camito Capistrano, Laguna Niguel, CA 91677 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.28(a)
(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.
Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.