Inspection 347539082 OPENED JUN 10, 2024Closed
248 Sands Road, Reidsville, NC 27320 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Raleigh, North Carolina · Industrial Building Construction · NAICS 236210
Southern Industrial Constructors, Inc. has 21 OSHA inspections on record in North Carolina, the first in 1990.
OSHA's last visit started on Jun 10, 2024 after a complaint, in Reidsville.
Across those inspections OSHA issued 24 citation items: 6 serious and 18 other-than-serious.
OSHA proposed $42,438 in penalties. After settlements and reviews the total is $39,500, down 7%.
Most often, OSHA cited 1926.251, rigging equipment for material handling (4 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Southern Industrial Constructors, Inc. averages $20,825 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Southern Industrial Constructors, Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
228employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Southern Industrial Constructors, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company248 Sands Road, Reidsville, NC 27320 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4600 Silicon Drive, Durham, NC 27703 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
Incident on Jul 17, 2023 (fatal): Employee sustains trauma in fall through floor, later dies
On July 17, 2023, an employee working for an industrial contractor in a commercial building was clearing the path for a scissor lift that was being used to help unload a crate of butterfly valves. While clearing the path, the employee had removed an unsecured 15/16-inch-thick plywood hole covering from the second-floor mezzanine of the building. While removing the plywood, the employee fell through the hole approximately 14 feet onto the concrete floor below. The employee was hospitalized to treat serious injuries to his spine and head, including a brain injury. He was pronounced dead the following day after withdrawal of life support.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(i)(3) · Fall protection systems |
Serious | $15,625 | $15,625 | Dec 15, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.1051(a) · Stairways and Ladders: general requirements |
Serious | $5,200 | $5,200 | Dec 15, 2023 | Final |
178 Avgol Drive, Mocksville, NC 27028 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3519 Glenwood Ave., Raleigh, NC 27612 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1225 Gastonia Technology Parkway, Dallas, NC 28034 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
865 John L. Riegel Rd, Riegelwood, NC 28456 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
Incident on May 2, 2012: Employees in contact with live electrical parts
On May 2, 2012 Employee #1 and Employee #2 of Southern Industrial Constructors, Inc. were installing jumper cable adjacent to a guarded 4160 volt starter bus. E mployee #1 removed the guard and inadvertently connected the energized bus, expo sing both employees to with live parts and arc flash.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $5,600 | $5,600 | Oct 26, 2012 | Final |
| Citation 1, item 2 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $5,600 | $5,600 | Oct 26, 2012 | Final |
| Citation 1, item 3 29 CFR 1926.416(a)(3) · Electrical safety in construction |
Serious | $6,300 | $6,300 | Oct 26, 2012 | Final |
801 Sutton Steam Plant Rd., Wilmington, NC 28401 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
14556 Hwy 601 South, Midland, NC 28107 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4851 Jones Sausage Road, Garner, NC 27529 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Unilin Hardwood Flooring - Industrial Drive, Thomasville, NC 27360 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Other-than-serious | $875 | $875 | Apr 6, 2005 | Closed |
| Citation 2, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Other-than-serious | $0 | $0 | Apr 6, 2005 | Closed |
Church Of The Good Shepherd, Raleigh, NC 27603 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.550(a)(9) · [Reserved] |
Other-than-serious | $2,250 | $0 | Aug 4, 2004 | Final |
3500 Daniels Rd., Leland, NC 28451 · Artificial and Synthetic Fibers and Filaments Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy 74 East, Laurinburg, NC 28353 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
State Port, Wilmington, NC 28412 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.251(a)(1) · Rigging equipment for material handling |
Other-than-serious | $688 | $0 | Oct 31, 2002 | Closed |
| Citation 1, item 1b 29 CFR 1926.251(e)(8) · Rigging equipment for material handling |
Other-than-serious | $0 | $0 | Oct 31, 2002 | Closed |
| Citation 1, item 2b 29 CFR 1926.550(a)(9) · [Reserved] |
Other-than-serious | $0 | $0 | Oct 31, 2002 | Closed |
| Citation 2, item 1 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Other-than-serious | $0 | $0 | Oct 31, 2002 | Closed |
701 Distribution Drive, Durham, NC 27709 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
411 Fayetteville Street, Raleigh, NC 27603 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.201(a)(4) · Signaling |
Other-than-serious | $0 | $0 | Mar 15, 1999 | Closed |
3813 S. Wilmington St., Raleigh, NC 27603 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.251(a)(1) · Rigging equipment for material handling |
Other-than-serious | $0 | $0 | Jan 29, 1999 | Closed |
| Citation 1, item 2 29 CFR 1926.251(a)(6) · Rigging equipment for material handling |
Other-than-serious | $0 | $0 | Jan 29, 1999 | Closed |
1203 S. Chicopee Road, Benson, NC 27504 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.152(e)(4) · Flammable liquids |
Other-than-serious | $0 | $0 | Aug 18, 1998 | Closed |
| Citation 1, item 2 29 CFR 1926.152(i)(2)(iif) · Flammable liquids |
Other-than-serious | $0 | $0 | Aug 18, 1998 | Closed |
| Citation 1, item 4 29 CFR 1926.405(a)(2)(iii) · Job-site wiring |
Other-than-serious | $0 | $0 | Aug 18, 1998 | Closed |
2215 South Wilmington St., Raleigh, NC 27603 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
816 Fieldcrest Rd., Eden, NC 27288 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(d)(2) · Medical services and first aid |
Other-than-serious | $0 | $0 | Jul 19, 1995 | Closed |
| Citation 1, item 2 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Other-than-serious | $0 | $0 | Jul 19, 1995 | Closed |
Sr 1400, Battleboro, NC 27509 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.28(a) · Personal protective equipment |
Serious | $300 | $300 | Mar 21, 1990 | Final |
| Citation 2, item 1 29 CFR 1926.150(a)(4) · Fire protection |
Other-than-serious | $0 | $0 | Mar 21, 1990 | Closed |
| Citation 2, item 2 29 CFR 1926.150(c)(1)(vi) · Fire protection |
Other-than-serious | $0 | $0 | Mar 21, 1990 | Closed |
| Citation 2, item 3 29 CFR 1926.450(a)(2) · Scope, application and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Mar 21, 1990 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Raleigh site logged 10 recordable injuries or illnesses among about 1,674 workers: 0.6 per 100 full-time workers, against a median of 1.5 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Southern Industrial Constructors Raleigh · 2025 | 1,674 | 10 | 0 | 0.6 | 1.5 |
| Southern Industrial Raleigh Raleigh · 2024 | 595 | 4 | 0 | 0.7 | 0.6 |
| Southern Industrial Constructors Wilmington Wilmington · 2024 | 350 | 1 | 0 | 0.3 | 0.6 |
Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.102(a)(1)
(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
29 CFR 1926.1051(a)
(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.
29 CFR 1926.150(a)(4)
(4) All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.