OSHA SearchOSHA records by employer

Southernwood Framing, LLC: OSHA inspections and violations

Easton, Maryland · Framing Contractors · NAICS 238130

5inspections
9citation items
$4,025current penalties
May 17, 2024last inspection

Since 2009, OSHA inspectors have visited Southernwood Framing, LLC in Maryland 5 times.

The most recent inspection opened on May 17, 2024, in Marriottsville.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $4,712; today they stand at $4,025, 15% less.

The rule cited most here is 1926.501 (fall protection in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Southernwood Framing, LLC averages $1,400 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Southernwood Framing, LLC: OSHA citation items per year, 2009 to 2024
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Southernwood Framing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347490534 OPENED MAY 17, 2024Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Aug 26, 2024

11712-11700 Keystones Lane, Marriottsville, MD 21104 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$1,400$1,400Jun 27, 2024Final

Inspection 346735277 OPENED JUN 9, 2023Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Sep 5, 2023

314 Bonny Way, Annapolis, MD 21403 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340075001 OPENED NOV 7, 2014Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Feb 6, 2015

Lot 14 Iverness 13800 Celadon Court, Hughesville, MD 20637 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 7, 2014 (fatal): Employee is killed in fall from roof truss

At approximately 2:30 p.m. on November 7, 2014, an employee was allegedly installing a bolt on a roof anchor which had allegedly been previously attached to a roof truss prior to being installed. The employee was located in the trusses themselves. The roof had already been sheathed. The employee fell from within the roof trusses, through the residence's stairway opening landing on the concrete basement floor located approximately 27 feet below. The employee was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$438$438Jan 8, 2015Final

Inspection 316285196 OPENED MAR 29, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 12, 2012

Brimstone Road, Units 96-101, Hanover, MD 21076 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$558Apr 26, 2012Closed
Citation 1, item 2
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$312$238Apr 26, 2012Closed
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$750$558Apr 26, 2012Closed
Citation 1, item 4
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$375$295Apr 26, 2012Closed
Citation 1, item 5
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$312$238Apr 26, 2012Closed

Inspection 313225104 OPENED JUN 19, 2009Closed

Planned · Complete · Safety · 1 employee at the site · Closed Aug 26, 2009

Lakelands At Easton, Superior Circle, Lots 57-60, Easton, MD 21601 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$375$300Jul 8, 2009Closed
Citation 1, item 1b
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$0$0Jul 8, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other framing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.