OSHA SearchOSHA records by employer

Southwest Construction Services, Inc.: OSHA inspections and violations

Port Charlotte, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

5inspections
7citation items
$14,703current penalties
Jun 23, 2025last inspection

OSHA has inspected Southwest Construction Services, Inc. 5 times in Florida since 2007.

The latest one began on Jun 23, 2025 as a planned inspection, in Moore Haven.

Those inspections ended with 7 citation items: 5 serious and 2 other-than-serious.

Penalties were first proposed at $22,855 and now stand at $14,703, 36% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Southwest Construction Services, Inc. averages $5,439 (2 cited inspections).

Southwest Construction Services, Inc.: OSHA citation items per year, 2007 to 2025
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Southwest Construction Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348325481 OPENED JUN 23, 2025Closed

Planned · Partial · Safety · 20 employees at the site · Closed Aug 15, 2025

400 West Ave, Moore Haven, FL 33471 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$7,945$4,767Jul 31, 2025Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,296$3,178Jul 31, 2025Final

Inspection 341877371 OPENED OCT 27, 2016Closed

Planned · Complete · Safety · 33 employees at the site · Closed Jul 21, 2017

384 Auba Circle, Bradenton, FL 34208 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Other-than-serious$4,889$2,933Feb 9, 2017Final
Citation 2, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Feb 9, 2017Final

Inspection 313103731 OPENED JUL 21, 2009Closed

Planned · Partial · Safety · 25 employees at the site · Closed Aug 10, 2009

13110 Ne 8th Ave., North Miami, FL 33161 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,125$1,125Jul 29, 2009Closed

Inspection 311769921 OPENED FEB 29, 2008Closed

Planned · Partial · Safety · 8 employees at the site · Closed Mar 17, 2008

49 S. Tamiami Trail, Osprey, FL 34229 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$2,250Mar 4, 2008Closed

Inspection 311676704 OPENED NOV 1, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 3, 2007

2120 Kings Highway, Port Charlotte, FL 33980 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$450Nov 13, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.