Southwest Electric Company: OSHA inspections and violations

Havelock, North Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
4citation items
$6,240current penalties
Mar 2, 2015last inspection

Southwest Electric Company has one OSHA inspection on record in North Carolina.

OSHA opened it on Mar 2, 2015 on a referral, in Havelock.

From that inspection OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

OSHA proposed $7,600 in penalties. After settlements and reviews the total is $6,240, down 18%.

Most often, OSHA cited 1910.269, electric power generation, transmission, and distribution (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Southwest Electric Company averages $6,240 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Southwest Electric Company: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Southwest Electric Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340449305 OPENED MAR 2, 2015Closed

Referral · Complete · Safety · 25 employees at the site · Closed Aug 19, 2015

Marine Core Air Station - Cherry Point, Havelock, NC 28532 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.269(m)(3)(ii) · Electric power generation, transmission, and distribution
Serious$2,800$2,800Jul 15, 2015Final
Citation 1, item 1b
29 CFR 1910.269(n)(3) · Electric power generation, transmission, and distribution
Serious$0$0Jul 15, 2015Final
Citation 1, item 2
29 CFR 1910.269(o)(2)(i) · Electric power generation, transmission, and distribution
Other-than-serious$2,800$2,800Jul 15, 2015Final
Citation 1, item 4
29 CFR 1910.335(a)(1)(ii) · Safeguards for personnel protection
Other-than-serious$2,000$640Jul 15, 2015Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 26, 2015, Havelock: Hospitalization · electrocutions, electric shocks · body systems

Employee was cleaning insulator bushings on top of a de-energized transformer/regulator in preparation for tap switch testing. Upon energizing of control voltage for testing, employee received an electric shock.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(m)(3)(ii)

(ii) The employer shall ensure that all switches, disconnectors, jumpers, taps, and other means through which known sources of electric energy may be supplied to the particular lines and equipment to be deenergized are open. The employer shall render such means inoperable, unless its design does not so permit, and then ensure that such means are tagged to indicate that employees are at work.

29 CFR 1910.269(n)(3)

(3) Equipotential zone. Temporary protective grounds shall be placed at such locations and arranged in such a manner that the employer can demonstrate will prevent each employee from being exposed to hazardous differences in electric potential.

29 CFR 1910.269(o)(2)(i)

(2) General requirements. (i) The employer shall establish and enforce work practices for the protection of each worker from the hazards of high-voltage or high-power testing at all test areas, temporary and permanent. Such work practices shall include, as a minimum, test area safeguarding, grounding, the safe use of measuring and control circuits, and a means providing for periodic safety checks of field test areas.

29 CFR 1910.335 · Safeguards for personnel protection

Other electrical contractors and other wiring installation contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.