Spectrum Electric, LLC: OSHA inspections and violations

Brooklyn, New York · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
3citation items
$4,560current penalties
May 2, 2019last inspection

OSHA has inspected Spectrum Electric, LLC 3 times in New York since 2008.

The latest one began on May 2, 2019, in Brooklyn.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $7,600 and now stand at $4,560, 40% lower after settlements or reviews.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Spectrum Electric, LLC averages $4,560 (1 cited inspection).

Spectrum Electric, LLC: OSHA citation items per year, 2008 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Spectrum Electric, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343979449 OPENED MAY 2, 2019Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Oct 29, 2019

2150 East 9 Street, Brooklyn, NY 11223 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341240349 OPENED JAN 29, 2016Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Sep 7, 2018

185 Atlantic Ave., Brooklyn, NY 11223 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,800$1,520Apr 4, 2016Final
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$2,400$1,520Apr 4, 2016Final
Citation 1, item 3
29 CFR 1926.405(j)(2) · Job-site wiring
Serious$2,400$1,520Apr 4, 2016Final

Inspection 310755434 OPENED MAY 14, 2008Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed May 16, 2008

Holiday Inn Express, 3603 Vestal Parkway, Vestal, NY 13850 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(j)(2)

(2) Receptacles, cord connectors, and attachment plugs (caps)—(i) Configuration. Receptacles, cord connectors, and attachment plugs shall be constructed so that no receptacle or cord connector will accept an attachment plug with a different voltage or current rating than that for which the device is intended. However, a 20-ampere T-slot receptacle or cord connector may accept a 15-ampere attachment plug of the same voltage rating. Receptacles connected to circuits having different voltages, frequencies, or types of current (ac or dc) on the same premises shall be of such design that the attachment plugs used on these circuits are not interchangeable.

Other electrical contractors and other wiring installation contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.