OSHA SearchOSHA records by employer

Speedco Inc: OSHA inspections and violations

Aurora, Oregon · Automotive Oil Change and Lubrication Shops · NAICS 811191

5inspections
11citation items
$440current penalties
Mar 17, 2022last inspection

Speedco Inc has 5 OSHA inspections on record in Oregon, the first in 2009.

OSHA's last visit started on Mar 17, 2022 as a planned inspection, in Aurora.

Across those inspections OSHA issued 11 citation items: 6 serious and 5 other-than-serious.

OSHA proposed $640 in penalties. After settlements and reviews the total is $440, down 31%.

Most often, OSHA cited 1910.1200, hazard communication (3 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Speedco Inc averages $113 over 3 cited inspections in that time.

Speedco Inc: OSHA citation items per year, 2009 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Speedco Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345943229 OPENED MAR 17, 2022Closed

Planned · Complete · Health · 14 employees at the site · Closed Oct 6, 2022

12227 Melinda Ln Ne, Aurora, OR 97002 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$300$100May 25, 2022Final
Citation 1, item 2a
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$120$120May 25, 2022Final
Citation 1, item 2b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0May 25, 2022Final

Inspection 343684940 OPENED DEC 20, 2018Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Jun 5, 2019

12227 Melinda Ln Ne, Aurora, OR 97002 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(e)(1) · Electrical wiring methods
Serious$120$120Jan 30, 2019Final
Citation 2, item 2
29 CFR OAR 437-001-0765(5)-3
Other-than-serious$0$0Jan 30, 2019Final
Citation 2, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jan 30, 2019Final

Inspection 341205706 OPENED JAN 26, 2016Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jun 24, 2016

12227 Melinda Ln Ne, Aurora, OR 97002 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.159(c)(2) · Automatic sprinkler systems
Other-than-serious$0$0Feb 29, 2016Final
Citation 1, item 2
29 CFR OAR 437-002-0187(2)-2
Other-than-serious$0$0Feb 29, 2016Final

Inspection 316637073 OPENED JAN 31, 2013Closed

Planned · Complete · Health · 18 employees at the site · Closed Oct 18, 2013

12227 Melinda Ln, Aurora, OR 97002 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Serious$100$100Apr 26, 2013Closed
Citation 1, item 1b Serious$0$0Apr 26, 2013Closed

Inspection 312719156 OPENED JUL 16, 2009Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jan 6, 2010

12227 Melinda Ln Ne, Aurora, OR 97002 · Automotive Oil Change and Lubrication Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 5, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.159 · Automatic sprinkler systems

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7650

29 CFR 7020.1341

Other automotive oil change and lubrication shops employers in Oregon

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.