OSHA SearchOSHA records by employer

Speedco: OSHA inspections and violations

Baytown, Texas · General Automotive Repair · NAICS 811111

1inspections
3citation items
$3,500current penalties
Oct 29, 2015last inspection

OSHA inspectors have visited Speedco in Texas one time.

It opened on Oct 29, 2015 on a referral, in Baytown.

In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

The proposed penalties came to $5,000; today they stand at $3,500, 30% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Speedco averages $3,500 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Speedco: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Speedco again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341025088 OPENED OCT 29, 2015Closed

Referral · Partial · Safety · 19 employees at the site · Closed Feb 12, 2016

2110 East Freeway, Baytown, TX 77521 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$5,000$3,500Nov 23, 2015Final
Citation 2, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 2015Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 2015Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 27, 2015, Baytown: Hospitalization · fractures and other injuries, unspecified · multiple body parts, n.e.c.

An employee was on an extension ladder approximately 20 feet high changing a light bulb. The employee fell from the ladder onto the cement floor and suffered a broken shoulder and possible brain injuries.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

Other general automotive repair employers in Texas