OSHA SearchOSHA records by employer

Spring Scaffolding, LLC.: OSHA inspections and violations

New York, New York · All Other Specialty Trade Contractors · NAICS 238990

13inspections
18citation items
$49,315current penalties
May 19, 2022last inspection

OSHA has inspected Spring Scaffolding, LLC. 13 times in New York since 1997.

The latest one began on May 19, 2022 on a referral, in Ridgewood.

Those inspections ended with 18 citation items: 9 serious, 2 repeat and 7 other-than-serious.

Penalties were first proposed at $77,516 and now stand at $49,315, 36% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 12 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Spring Scaffolding, LLC. averages $18,000 (1 cited inspection).

Spring Scaffolding, LLC.: OSHA citation items per year, 1997 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Spring Scaffolding, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345972251 OPENED MAY 19, 2022Closed

Referral · Records only · Safety · 8 employees at the site · Closed Nov 18, 2022

3-50 St Nicholas Avenue, Ridgewood, NY 11385 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345636864 OPENED OCT 18, 2021Closed

Unprogrammed other · Partial · Safety · 139 employees at the site · Closed Sep 19, 2022

20 Buckner Blvd, Bronx, NY 10454 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342401627 OPENED JUN 8, 2017Closed

Planned · Complete · Safety · 150 employees at the site · Closed Sep 25, 2018

123 Baxter Street, New York, NY 10013 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$8,149$6,000Dec 6, 2017Final
Citation 2, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$16,297$12,000Dec 6, 2017Final

Inspection 341835353 OPENED OCT 13, 2016Closed

Complaint · Partial · Safety · 39 employees at the site · Closed Oct 21, 2016

55-51 43rd Street, Maspeth, NY 11378 · Other Warehousing and Storage · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339563025 OPENED JAN 24, 2014Closed

Unprogrammed other · Complete · Safety · 50 employees at the site · Closed Jul 18, 2014

20 East 64th Street, New York, NY 10065 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339332439 OPENED AUG 20, 2013Closed

Referral · Complete · Safety · 60 employees at the site · Closed Dec 22, 2014

14 Wall St, Aka 9 Pine St, New York, NY 10005 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(c) · Scaffold training
Other-than-serious$5,390$4,042Dec 2, 2013Final
Citation 2, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Other-than-serious$10,780$4,042Dec 2, 2013Final

Inspection 338988280 OPENED APR 3, 2013Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Jan 15, 2014

501 87th Street, New York, NY 10128 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$3,500$3,150May 8, 2013Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$3,500$3,150May 8, 2013Final

Inspection 314881574 OPENED SEP 9, 2010Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 9, 2010

346 W. 17th St, New York, NY 10011 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

5 older inspections

Inspection 314595679 OPENED JUN 9, 2010Closed

Unprogrammed related · Complete · Safety · 9 employees at the site · Closed Aug 17, 2010

370 Park Ave., New York, NY 10022 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306989062 OPENED OCT 7, 2003Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Jul 1, 2004

43 Central Avenue, Brooklyn, NY 11206 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$7,000$0Oct 24, 2003Final

Inspection 304943632 OPENED OCT 12, 2001Closed

Planned · Partial · Safety · 80 employees at the site · Closed Dec 27, 2001

Corner Of Church And Warren Streets, New York, NY 10007 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$3,000$1,800Oct 16, 2001Closed
Citation 2, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Repeat$3,000$1,800Oct 16, 2001Closed

Inspection 300619301 OPENED NOV 18, 1998Closed

Referral · Complete · Safety · 30 employees at the site · Closed Jan 19, 1999

345 Hudson Street, New York, NY 10014 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$900$630Dec 7, 1998Closed
Citation 1, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$2,500$1,750Dec 7, 1998Closed
Citation 1, item 3
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$3,000$2,100Nov 30, 1998Closed
Citation 1, item 4
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$3,000$2,100Dec 7, 1998Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Dec 7, 1998Closed

Inspection 300613577 OPENED FEB 25, 1997Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Sep 18, 1997

75 Clinton Street, Brooklyn, NY 11201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$2,500$2,500May 9, 1997Closed
Citation 1, item 2
29 CFR 1926.451(e)(4)(i) · Scaffolds, general requirements
Serious$1,250$1,250May 9, 1997Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,250$1,250May 9, 1997Closed
Citation 2, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$2,500$1,750Jul 23, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.