Inspection 345972251 OPENED MAY 19, 2022Closed
3-50 St Nicholas Avenue, Ridgewood, NY 11385 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Spring Scaffolding, LLC. 13 times in New York since 1997.
The latest one began on May 19, 2022 on a referral, in Ridgewood.
Those inspections ended with 18 citation items: 9 serious, 2 repeat and 7 other-than-serious.
Penalties were first proposed at $77,516 and now stand at $49,315, 36% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 12 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Spring Scaffolding, LLC. averages $18,000 (1 cited inspection).
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Spring Scaffolding, LLC. and get notified the morning OSHA posts a new citation for it.
Watch this company3-50 St Nicholas Avenue, Ridgewood, NY 11385 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
20 Buckner Blvd, Bronx, NY 10454 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
123 Baxter Street, New York, NY 10013 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Other-than-serious | $8,149 | $6,000 | Dec 6, 2017 | Final |
| Citation 2, item 1 29 CFR 1926.451(g)(2) · Scaffolds, general requirements |
Serious | $16,297 | $12,000 | Dec 6, 2017 | Final |
55-51 43rd Street, Maspeth, NY 11378 · Other Warehousing and Storage · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
20 East 64th Street, New York, NY 10065 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
14 Wall St, Aka 9 Pine St, New York, NY 10005 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.454(c) · Scaffold training |
Other-than-serious | $5,390 | $4,042 | Dec 2, 2013 | Final |
| Citation 2, item 1 29 CFR 1926.451(g)(2) · Scaffolds, general requirements |
Other-than-serious | $10,780 | $4,042 | Dec 2, 2013 | Final |
501 87th Street, New York, NY 10128 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Other-than-serious | $3,500 | $3,150 | May 8, 2013 | Final |
| Citation 1, item 2 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Other-than-serious | $3,500 | $3,150 | May 8, 2013 | Final |
346 W. 17th St, New York, NY 10011 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
370 Park Ave., New York, NY 10022 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
43 Central Avenue, Brooklyn, NY 11206 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Other-than-serious | $7,000 | $0 | Oct 24, 2003 | Final |
Corner Of Church And Warren Streets, New York, NY 10007 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Repeat | $3,000 | $1,800 | Oct 16, 2001 | Closed |
| Citation 2, item 2 29 CFR 1926.451(g)(2) · Scaffolds, general requirements |
Repeat | $3,000 | $1,800 | Oct 16, 2001 | Closed |
345 Hudson Street, New York, NY 10014 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $900 | $630 | Dec 7, 1998 | Closed |
| Citation 1, item 2 29 CFR 1926.451(g)(2) · Scaffolds, general requirements |
Serious | $2,500 | $1,750 | Dec 7, 1998 | Closed |
| Citation 1, item 3 29 CFR 1926.501(b)(3) · Fall protection in construction |
Serious | $3,000 | $2,100 | Nov 30, 1998 | Closed |
| Citation 1, item 4 29 CFR 1926.503(a)(2) · Fall protection training in construction |
Serious | $3,000 | $2,100 | Dec 7, 1998 | Closed |
| Citation 2, item 1 29 CFR 1904.2(a) · Partial exemption for establishments in certain industries |
Other-than-serious | $0 | $0 | Dec 7, 1998 | Closed |
75 Clinton Street, Brooklyn, NY 11201 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(a)(6) · Scaffolds, general requirements |
Serious | $2,500 | $2,500 | May 9, 1997 | Closed |
| Citation 1, item 2 29 CFR 1926.451(e)(4)(i) · Scaffolds, general requirements |
Serious | $1,250 | $1,250 | May 9, 1997 | Closed |
| Citation 1, item 3 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $1,250 | $1,250 | May 9, 1997 | Closed |
| Citation 2, item 1 29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements |
Serious | $2,500 | $1,750 | Jul 23, 1997 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.451(a)(6)
(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.
29 CFR 1926.451(c)(1)(ii)
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.