Springfield - Electric: OSHA inspections and violations

Springfield, Tennessee · Electric Power Distribution · NAICS 221122

4inspections
11citation items
$0current penalties
Jun 18, 2021last inspection

Since 1987, OSHA inspectors have visited Springfield - Electric in Tennessee 4 times.

The most recent inspection opened on Jun 18, 2021 as a planned inspection, in Springfield.

In all, OSHA issued 11 citation items: 9 serious and 2 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 4 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Springfield - Electric averages $0 across 1 cited inspection.

Springfield - Electric: OSHA citation items per year, 1987 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Springfield - Electric again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345371884 OPENED JUN 18, 2021Closed

Planned · Complete · Safety · Local government · 19 employees at the site · Closed Jul 22, 2021

1000 Central Avenue West, Springfield, TN 37172 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jun 29, 2021Final
Citation 1, item 2
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Jun 29, 2021Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jun 29, 2021Final
Citation 1, item 4
29 CFR TDLWD RULE 800-01-09-.06(2)
Serious$0$0Jun 29, 2021Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-03-.03(27)(A)
Other-than-serious$0$0Jun 29, 2021Final

Inspection 317680197 OPENED MAR 11, 2014Closed

Planned · Complete · Safety · Local government · 18 employees at the site · Closed Apr 14, 2014

718 Central Street, Springfield, TN 37172 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Serious$0$0Mar 20, 2014Closed
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Mar 20, 2014Closed
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Mar 20, 2014Closed
Citation 1, item 4
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Serious$0$0Mar 20, 2014Closed

Inspection 111084752 OPENED AUG 27, 1991Closed

Planned · Complete · Safety · Local government · 16 employees at the site · Closed Oct 17, 1991

718 Central Street, Springfield, TN 37172 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 11, 1991Closed

Inspection 105536569 OPENED JUN 9, 1987Closed

Planned · Complete · Safety · Local government · 16 employees at the site · Closed Feb 13, 1989

718 Central Street, Springfield, TN 37172 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$0$0Jun 19, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(a)(2)

(2) Guard design. The safety guard shall cover the spindle end, nut, and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard, except:

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.303(g)(1)(i)

(i) Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes