OSHA SearchOSHA records by employer

Spurry Builders, Inc.: OSHA inspections and violations

Saint Michaels, Maryland · Siding Contractors · NAICS 238170

1inspections
3citation items
$0current penalties
Nov 8, 2018last inspection

Spurry Builders, Inc. has one OSHA inspection on record in Maryland.

OSHA opened it on Nov 8, 2018 as a planned inspection, in Saint Michaels.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Spurry Builders, Inc. averages $0 over 1 cited inspection in that time.

Spurry Builders, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

195employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Spurry Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343589883 OPENED NOV 8, 2018Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 13, 2019

102 Fremont Street, Saint Michaels, MD 21663 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Dec 26, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Dec 26, 2018Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Dec 26, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other siding contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.