OSHA SearchOSHA records by employer

SRQ Framing LLC: OSHA inspections and violations

Holmes Beach, Florida · Framing Contractors · NAICS 238130

1inspections
5citation items
$4,620current penalties
Mar 17, 2015last inspection

OSHA inspectors have visited SRQ Framing LLC in Florida one time.

It opened on Mar 17, 2015 as a planned inspection, in Holmes Beach.

In all, OSHA issued 5 citation items: 3 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $9,240; today they stand at $4,620, 50% less.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. SRQ Framing LLC averages $4,620 across 1 cited inspection.

SRQ Framing LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

43 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch SRQ Framing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340473867 OPENED MAR 17, 2015Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 27, 2015

120 Neptune Lane, Holmes Beach, FL 34217 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,080$1,540May 5, 2015Final
Citation 1, item 1b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0May 5, 2015Final
Citation 1, item 1c
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0May 5, 2015Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$6,160$3,080May 5, 2015Final
Citation 3, item 1
29 CFR 1926.403(b)(1)(iii) · Electrical equipment on job sites
Other-than-serious$0$0May 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(iii)

(iii) Electrical insulation.

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.