OSHA SearchOSHA records by employer

Stackhouse Athletic Equipment Inc: OSHA inspections and violations

Salem, Oregon · Sporting and Athletic Goods Manufacturing · NAICS 339920

6inspections
21citation items
$845current penalties
Oct 8, 2019last inspection

Stackhouse Athletic Equipment Inc has 6 OSHA inspections on record in Oregon, the first in 1988.

OSHA's last visit started on Oct 8, 2019 as a planned inspection, in Salem.

Across those inspections OSHA issued 21 citation items: 9 serious and 12 other-than-serious.

OSHA proposed $845 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Stackhouse Athletic Equipment Inc averages $100 over 1 cited inspection in that time.

Stackhouse Athletic Equipment Inc: OSHA citation items per year, 1988 to 2019
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Stackhouse Athletic Equipment Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344363734 OPENED OCT 8, 2019Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 18, 2020

1450 Mcdonald St Ne, Salem, OR 97301 · Sporting and Athletic Goods Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$100$100Oct 31, 2019Final

Inspection 313676819 OPENED OCT 23, 2009Closed

Planned · Complete · Health · 10 employees at the site · Closed Mar 29, 2010

1450 Mcdonald St Ne, Salem, OR 97301 · Sporting and Athletic Goods Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$100$100Dec 24, 2009Closed
Citation 1, item 1b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Dec 24, 2009Closed
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$165$165Dec 24, 2009Closed
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 24, 2009Closed
Citation 2, item 3
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 24, 2009Closed
Citation 2, item 4
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 24, 2009Closed
Citation 2, item 5 Other-than-serious$0$0Dec 24, 2009Closed

Inspection 302052923 OPENED DEC 17, 1998Closed

Planned · Complete · Safety · 8 employees at the site · Closed Dec 17, 1998

1450 Mcdonald Street Ne, Salem, OR 97303 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126223445 OPENED MAR 29, 1995Closed

Planned · No inspection · Safety · Closed Mar 29, 1995

2915-b Evanston Ne, Salem, OR 97303 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126223452 OPENED MAR 29, 1995Closed

Planned · Complete · Safety · 14 employees at the site · Closed May 10, 1995

1450 Mcdonald Street Ne, Salem, OR 97303 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$120$120Apr 19, 1995Closed
Citation 1, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$120$120Apr 19, 1995Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 19, 1995Closed
Citation 2, item 4
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Apr 19, 1995Closed

Inspection 105270029 OPENED JUL 29, 1988Closed

Planned · Complete · Safety · 9 employees at the site · Closed Sep 23, 1988

1501 Front St Ne, Salem, OR 97303 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$120$120Aug 10, 1988Closed
Citation 1, item 2 Serious$120$120Aug 10, 1988Closed
Citation 2, item 3 Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 4 Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 5
29 CFR 7410045
Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 6 Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 7 Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 8 Other-than-serious$0$0Aug 10, 1988Closed
Citation 2, item 9 Other-than-serious$0$0Aug 10, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7650

29 CFR 7127.20

29 CFR 7127.30

29 CFR 7155.15

29 CFR 7155.30

29 CFR 7410.2700

29 CFR 7610.700

29 CFR 7640.2550

29 CFR 7640.2650

Other sporting and athletic goods manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.