Inspection 345298046 OPENED MAY 10, 2021Closed
156 E. 162nd St., Gardena, CA 90248 · Temporary Help Services · OSHA's record · Phone and website on Google Maps
Incident on Apr 6, 2021: Employee's finger is amputated by encapsulation machine
At approximately 4:30 p.m. on April 6, 2021, Employee #1, an employee of Staff Force Personnel Services assigned to West Coast Laboratories, Inc., was working in the Capsule Building on machine 9, a Bohanan VersiFil hard gelatin encapsulation machine. While operating the machine, Employee #1 opened the front doors and attempted to loosen stuck gelatin capsules using his left hand, while the machine was still running. Employee #1's right index finger was pulled into the moving turret that closes the capsules, resulting in an amputation of his right index fingertip. The incident occurred despite conflicting accounts of how the machine and interlock functions were being operated at the time. Employee #1 was admitted and treated at Dignity Health/California Hospital in Los Angeles.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 3203(A) |
Other-than-serious | $750 | $280 | Oct 6, 2021 | Final |
| Citation 1, item 2 29 CFR 3205(C) |
Other-than-serious | $750 | $280 | Oct 6, 2021 | Final |
| Citation 2, item 1 29 CFR 4184(B) |
Other-than-serious | $18,000 | $750 | Oct 6, 2021 | Final |