OSHA SearchOSHA records by employer

Standard Stucco General: OSHA inspections and violations

Westbury, New York · Residential Remodelers · NAICS 236118

1inspections
3citation items
$10,641current penalties
Mar 20, 2026last inspection

OSHA inspectors have visited Standard Stucco General in New York one time.

It opened on Mar 20, 2026, in Westbury and is still open.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $10,641 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Standard Stucco General averages $10,641 across 1 cited inspection.

Standard Stucco General: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Standard Stucco General and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348839184 OPENED MAR 20, 2026Open

Inspection · Partial · Safety · 3 employees at the site · Open

745 Carmens Ave, Westbury, NY 11568 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,547$3,547May 28, 2026Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,547$3,547May 28, 2026Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,547$3,547May 28, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other residential remodelers employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.