Inspection 343792859 OPENED FEB 15, 2019Closed
1431 Taylor St, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Stapleton Timber & Excavation Inc has 7 OSHA inspections on record in Oregon, the first in 2008.
OSHA's last visit started on Feb 15, 2019 as a planned inspection, in Eugene.
Across those inspections OSHA issued 8 citation items: 3 serious and 5 other-than-serious.
OSHA proposed $300 in penalties and the amount has not been reduced.
Most often, OSHA cited 7020.1870, (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Stapleton Timber & Excavation Inc averages $50 over 2 cited inspections in that time.
Oregon · latest 90 days of OSHA records
388employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Stapleton Timber & Excavation Inc and get notified the morning OSHA posts a new citation for it.
Watch this company1431 Taylor St, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3505 Commercial Ave, Springfield, OR 97478 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-002-0210(2)(B)(A) |
Serious | $100 | $100 | Mar 14, 2019 | Final |
Hatfield Estates Bottom Loop Rd, Coburg, OR 97408 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-001-0765(13)-1 |
Other-than-serious | $0 | $0 | Aug 30, 2016 | Final |
1270 Irvington Rd, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1709 Irving Rd, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $100 | $100 | Jul 26, 2013 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Jul 26, 2013 | Closed |
| Citation 2, item 3 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 26, 2013 | Closed |
| Citation 2, item 4 | Other-than-serious | $0 | $0 | Jul 26, 2013 | Closed |
| Citation 2, item 5 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Jul 26, 2013 | Closed |
5509 Tribute Way, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $100 | $100 | Sep 28, 2009 | Closed |
3885 Janissen St Bldg C, Eugene, OR 97402 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(g)(1)
(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1926.701(b)
(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.