OSHA SearchOSHA records by employer

Star Kings LLC: OSHA inspections and violations

Glendale, Arizona · Other Direct Selling Establishments · NAICS 454390

1inspections
3citation items
$0current penalties
Nov 5, 2015last inspection

OSHA inspectors have visited Star Kings LLC in Arizona one time.

It opened on Nov 5, 2015 as part of a related case, in Glendale.

In all, OSHA issued 3 citation items: 3 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among retail employers, the typical cited inspection since 2015 ends with a $2,128 penalty. Star Kings LLC averages $0 across 1 cited inspection.

Star Kings LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Star Kings LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341038347 OPENED NOV 5, 2015Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Feb 16, 2016

7700 W Arrowhead Towne Center Ctr Kiosk Level 1, Glendale, AZ 85308 · Other Direct Selling Establishments · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2016Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2016Final
Citation 1, item 3
29 CFR 1910.305(j)(2)(v) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(ii)

(ii) Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1910.305(j)(2)(v)

(v) A receptacle installed outdoors in a location protected from the weather or in other damp locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered (attachment plug cap not inserted and receptacle covers closed).