OSHA SearchOSHA records by employer

State Remodeling LLC: OSHA inspections and violations

Honolulu, Hawaii · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

6inspections
22citation items
$8,222current penalties
Dec 22, 2015last inspection

OSHA has inspected State Remodeling LLC 6 times in Hawaii since 2005.

The latest one began on Dec 22, 2015 on a referral, in Honolulu.

Those inspections ended with 22 citation items: 17 serious and 5 other-than-serious.

Penalties were first proposed at $11,425 and now stand at $8,222, 28% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and State Remodeling LLC averages $3,330 (1 cited inspection).

State Remodeling LLC: OSHA citation items per year, 2005 to 2015
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

64employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch State Remodeling LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341137339 OPENED DEC 22, 2015Closed

Referral · Complete · Safety · 5 employees at the site · Closed Mar 3, 2016

3722 Harding Ave, Honolulu, HI 96815 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,050$630Feb 8, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,050$630Feb 8, 2016Final
Citation 1, item 3
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$750$450Feb 8, 2016Final
Citation 1, item 4
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,200$720Feb 8, 2016Final
Citation 1, item 5
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$750$450Feb 8, 2016Final
Citation 1, item 6
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$750$450Feb 8, 2016Final
Citation 2, item 1
29 CFR 12-110-3(C)
Other-than-serious$0$0Feb 8, 2016Final

Inspection 313080020 OPENED APR 26, 2010Closed

Referral · Partial · Safety · 5 employees at the site · Closed Dec 8, 2010

330 Awini Way, Honolulu, HI 96825 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,000$750Sep 27, 2010Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$800$580Sep 27, 2010Closed
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$800$580Sep 27, 2010Closed
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Sep 27, 2010Closed
Citation 2, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Sep 27, 2010Closed
Citation 2, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Sep 27, 2010Closed
Citation 2, item 4
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Sep 27, 2010Closed

Inspection 313075079 OPENED APR 12, 2010Closed

Follow-up · No inspection · Safety · Closed Apr 12, 2010

330 Awini Way, Honolulu, HI 96825 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313075244 OPENED APR 12, 2010Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jul 9, 2010

2716 Oahu Ave, Honolulu, HI 96822 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,000$1,000Jun 2, 2010Closed
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$1,000$1,000Jun 2, 2010Closed

Inspection 311437644 OPENED MAR 9, 2009Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 12, 2010

1221 S King St, Honolulu, HI 96814 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1100002 A02
Serious$375$285Jul 13, 2009Final
Citation 1, item 2a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$375$285Jul 13, 2009Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jul 13, 2009Final
Citation 1, item 2c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jul 13, 2009Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$225$112Jul 13, 2009Final

Inspection 308484930 OPENED MAR 28, 2005Closed

Referral · Partial · Safety · 6 employees at the site · Closed Jun 14, 2005

2226 Piimauna St, Honolulu, HI 96821 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$300$300May 23, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other new single-family housing construction (except for-sale builders) employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.