OSHA SearchOSHA records by employer

Stewart Knives, LLC dba Bark River Knives: OSHA inspections and violations

Escanaba, Michigan · Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing · NAICS 332215

2inspections
16citation items
$19,500current penalties
Jun 2, 2021last inspection

Since 2021, OSHA inspectors have visited Stewart Knives, LLC dba Bark River Knives in Michigan 2 times.

The most recent inspection opened on Jun 2, 2021 as a planned inspection, in Escanaba.

In all, OSHA issued 16 citation items: 4 serious, 6 repeat and 6 other-than-serious.

The penalties, $19,500 in total, stand where OSHA first set them.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Stewart Knives, LLC dba Bark River Knives averages $9,750 across 2 cited inspections.

Stewart Knives, LLC dba Bark River Knives: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

617employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Stewart Knives, LLC dba Bark River Knives and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345339477 OPENED JUN 2, 2021Closed

Planned · Partial · Safety · 47 employees at the site · Closed Jan 3, 2024

6911 County 426 M.5 Rd, Escanaba, MI 49829 · Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12722(2)
Serious$3,000$3,000Jul 15, 2021Final
Citation 2, item 1a
29 CFR 408.22129(1)
Other-than-serious$500$500Jul 15, 2021Final
Citation 2, item 1b
29 CFR 408.22129(4)
Other-than-serious$0$0Jul 15, 2021Final

Inspection 345341259 OPENED JUN 2, 2021Open

Planned · Complete · Safety · 47 employees at the site · Open

6911 County 426 M.5 Rd, Escanaba, MI 49829 · Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.11441
Serious$2,500$2,500Jul 23, 2021Contested
Citation 1, item 2
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$4,200$4,200Jul 23, 2021Contested
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,500$2,500Jul 23, 2021Contested
Citation 2, item 1a
29 CFR 408.11115(1)
Repeat$6,000$6,000Jul 23, 2021Contested
Citation 2, item 1b
29 CFR 408.11115(2)
Repeat$0$0Jul 23, 2021Contested
Citation 2, item 1c
29 CFR 408.11115(4)
Repeat$0$0Jul 23, 2021Contested
Citation 3, item 1a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Repeat$400$400Jul 23, 2021Contested
Citation 3, item 1b
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Repeat$0$0Jul 23, 2021Contested
Citation 3, item 2
29 CFR 408.11111(B)
Repeat$400$400Jul 23, 2021Contested
Citation 4, item 1a
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 23, 2021Contested
Citation 4, item 1b
29 CFR 1910.305(c)(4) · Electrical wiring methods
Other-than-serious$0$0Jul 23, 2021Contested
Citation 4, item 2
29 CFR 408.10685(3)
Other-than-serious$0$0Jul 23, 2021Contested
Citation 4, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 23, 2021Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

Other metal kitchen cookware, utensil, cutlery, and flatware (except precious) manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.