OSHA SearchOSHA records by employer

Stma Services, LLC: OSHA inspections and violations

Wesley Chapel, North Carolina · Siding Contractors · NAICS 238170

1inspections
5citation items
$4,290current penalties
Mar 15, 2018last inspection

Stma Services, LLC has one OSHA inspection on record in North Carolina.

OSHA opened it on Mar 15, 2018 as a planned inspection, in Wesley Chapel.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $6,600 in penalties. After settlements and reviews the total is $4,290, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Stma Services, LLC averages $4,290 over 1 cited inspection in that time.

Stma Services, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Stma Services, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343031688 OPENED MAR 15, 2018Closed

Planned · Partial · Health · 7 employees at the site · Closed Apr 1, 2024

105 Walker Falls Way (lot #146), Wesley Chapel, NC 28104 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$900$585Apr 16, 2018Final
Citation 1, item 2
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$1,500$975Apr 16, 2018Final
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,100$1,365Apr 16, 2018Final
Citation 1, item 3b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Apr 16, 2018Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,100$1,365Apr 16, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.