OSHA SearchOSHA records by employer

STMR, Inc.: OSHA inspections and violations

Hackensack, New Jersey · Masonry Contractors · NAICS 238140

5inspections
7citation items
$27,857current penalties
Oct 14, 2022last inspection

OSHA has inspected STMR, Inc. 5 times in New Jersey since 2019.

The latest one began on Oct 14, 2022 after a complaint, in Parsippany.

Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $52,273 and now stand at $27,857, 47% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and STMR, Inc. averages $13,928 (2 cited inspections).

STMR, Inc.: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch STMR, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346311111 OPENED OCT 14, 2022Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 14, 2023

100 Cherry Hill Rd., Parsippany, NJ 07054 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346119852 OPENED AUG 3, 2022Closed

Planned · Partial · Safety · 30 employees at the site · Closed Aug 2, 2023

443 Route 17s, Paramus, NJ 07652 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$11,167$7,300Aug 22, 2022Final

Inspection 345689160 OPENED DEC 14, 2021Closed

Unprogrammed other · Complete · Safety · 35 employees at the site · Closed Jul 12, 2022

300 Riverfront Blvd, Elmwood Park, NJ 07407 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345277669 OPENED APR 28, 2021Closed

Follow-up · No inspection · Safety · Closed Apr 28, 2021

210 Main Street, Hackensack, NJ 07601 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343888798 OPENED MAR 28, 2019Closed

Planned · Partial · Safety · 35 employees at the site · Closed Dec 28, 2022

210 Main St, Hackensack, NJ 07601 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$5,304$4,150Aug 19, 2019Final
Citation 1, item 2
29 CFR 1926.451(d)(3)(iv) · Scaffolds, general requirements
Serious$6,630$5,469Aug 19, 2019Final
Citation 1, item 3
29 CFR 1926.451(d)(3)(vi) · Scaffolds, general requirements
Serious$6,630$5,469Aug 19, 2019Final
Citation 1, item 4
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$6,630$0Aug 19, 2019Final
Citation 1, item 5
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$9,282$0Aug 19, 2019Final
Citation 1, item 6
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$6,630$5,469Aug 19, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(3)(iv)

(iv) Counterweights shall be secured by mechanical means to the outrigger beams to prevent accidental displacement.

29 CFR 1926.451(d)(3)(vi)

(vi) Outrigger beams which are not stabilized by bolts or other direct connections to the floor or roof deck shall be secured by tiebacks.

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.