Stokes Construction: OSHA inspections and violations

Cranberry Township, Pennsylvania · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
3citation items
$2,000current penalties
Oct 26, 2015last inspection

OSHA inspectors have visited Stokes Construction in Pennsylvania one time.

It opened on Oct 26, 2015 as a planned inspection, in Cranberry Township.

In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

The penalties, $2,000 in total, stand where OSHA first set them.

The rule cited most here is 1926.351 (arc welding and cutting), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Stokes Construction averages $2,000 across 1 cited inspection.

Stokes Construction: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Stokes Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341014058 OPENED OCT 26, 2015Closed

Planned · Partial · Safety · 7 employees at the site · Closed Dec 8, 2015

20117 Route 19, Cranberry Township, PA 16066 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,000$2,000Nov 2, 2015Final
Citation 2, item 1
29 CFR 1926.351(b)(2) · Arc welding and cutting
Other-than-serious$0$0Nov 2, 2015Final
Citation 2, item 2
29 CFR 1926.351(b)(4) · Arc welding and cutting
Other-than-serious$0$0Nov 2, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.351(b)(2)

(2) Only cable free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder is connected shall be used, except that cables with standard insulated connectors or with splices whose insulating quality is equal to that of the cable are permitted.

29 CFR 1926.351(b)(4)

(4) Cables in need of repair shall not be used. When a cable, other than the cable lead referred to in paragraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tape or other equivalent insulation.

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(a)(1)

(a) General requirements. (1) Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.

Other structural steel and precast concrete contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.