OSHA SearchOSHA records by employer

Stoltzfus, LLC: OSHA inspections and violations

Middletown, Delaware · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
7citation items
$16,250current penalties
Aug 5, 2022last inspection

OSHA inspectors have visited Stoltzfus, LLC in Delaware one time.

It opened on Aug 5, 2022 on a referral, in Middletown.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $25,000; today they stand at $16,250, 35% less.

The rule cited most here is 1926.651 (excavations), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Stoltzfus, LLC averages $16,250 across 1 cited inspection.

Stoltzfus, LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Stoltzfus, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346127822 OPENED AUG 5, 2022Closed

Referral · Partial · Safety · 7 employees at the site · Closed Feb 23, 2023

1825 Lake Seymour Drive, Middletown, DE 19709 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$6,250$4,062Feb 1, 2023Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$6,250$4,062Feb 1, 2023Final
Citation 1, item 3b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Feb 1, 2023Final
Citation 1, item 4a
29 CFR 1926.651(k)(1) · Excavations
Serious$6,250$4,062Feb 1, 2023Final
Citation 1, item 4b
29 CFR 1926.651(k)(2) · Excavations
Serious$0$0Feb 1, 2023Final
Citation 1, item 4c
29 CFR 1926.651(l) · Excavations
Serious$0$0Feb 1, 2023Final
Citation 1, item 5
29 CFR 1926.652(a)(1) · Trench protection
Serious$6,250$4,062Feb 1, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Delaware

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.