OSHA SearchOSHA records by employer

Stoltzfus R.V.'s, Inc.: OSHA inspections and violations

Adamstown, Pennsylvania · Recreational Vehicle Dealers · NAICS 441210

2inspections
5citation items
$6,200current penalties
Feb 25, 2016last inspection

Stoltzfus R.V.'s, Inc. has 2 OSHA inspections on record in Pennsylvania, the first in 2015.

OSHA's last visit started on Feb 25, 2016 to follow up on an earlier case, in Adamstown.

Across those inspections OSHA issued 5 citation items: 3 serious, 1 repeat and 1 other-than-serious.

OSHA proposed $9,600 in penalties. After settlements and reviews the total is $6,200, down 35%.

Most often, OSHA cited 1910.23, ladders in general industry (2 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Stoltzfus R.V.'s, Inc. averages $3,100 over 2 cited inspections in that time.

Stoltzfus R.V.'s, Inc.: OSHA citation items per year, 2015 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Stoltzfus R.V.'s, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341286920 OPENED FEB 25, 2016Closed

Follow-up · Partial · Safety · 15 employees at the site · Closed Oct 18, 2016

Rt 272 3280 North Reading Road Po Box 564, Adamstown, PA 19501 · Recreational Vehicle Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Repeat$4,000$2,000Jul 29, 2016Final

Inspection 340725191 OPENED JUN 23, 2015Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Aug 4, 2016

3280 North Reading Road Route 272, Adamstown, PA 19501 · Recreational Vehicle Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,000$1,500Dec 17, 2015Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,600$1,200Dec 17, 2015Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,000$1,500Dec 17, 2015Final
Citation 2, item 1
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(b)(9)

(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

Other recreational vehicle dealers employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.