OSHA SearchOSHA records by employer

Storage Construction Company, LLC: OSHA inspections and violations

Bronx, New York · Commercial and Institutional Building Construction · NAICS 236220

4inspections
9citation items
$10,194current penalties
Sep 28, 2017last inspection

Since 2007, OSHA inspectors have visited Storage Construction Company, LLC in New York 4 times.

The most recent inspection opened on Sep 28, 2017 after a complaint, in Bronx.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $12,444; today they stand at $10,194, 18% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Storage Construction Company, LLC averages $6,519 across 1 cited inspection.

Storage Construction Company, LLC: OSHA citation items per year, 2007 to 2017
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Storage Construction Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342673357 OPENED SEP 28, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Dec 28, 2017

2880 Exterior St., Bronx, NY 10463 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,897$2,897Nov 9, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,622$3,622Nov 9, 2017Final

Inspection 313433971 OPENED FEB 6, 2012Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Feb 6, 2012

33-24 Woodside Avenue, Woodside, NY 11377 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313427338 OPENED APR 22, 2010Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Mar 7, 2011

124-16 31st Ave., Flushing, NY 11354 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$375$375Sep 24, 2010Closed
Citation 1, item 1b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 24, 2010Closed
Citation 2, item 1
29 CFR 1926.350(a)(10) · Gas welding and cutting
Other-than-serious$0$0Sep 24, 2010Closed

Inspection 309599702 OPENED MAY 23, 2007Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 4, 2008

1980 White Plains Road, Bronx, NY 10462 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$825Jun 21, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,050$825Jun 21, 2007Closed
Citation 1, item 3
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$1,500$825Jun 21, 2007Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,500$825Jun 21, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(10)

(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.