OSHA SearchOSHA records by employer

Storagexpress Corp.: OSHA inspections and violations

District Heights, Maryland · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$875current penalties
Sep 16, 2020last inspection

OSHA inspectors have visited Storagexpress Corp. in Maryland one time.

It opened on Sep 16, 2020 as part of a related case, in District Heights.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The penalties, $875 in total, stand where OSHA first set them.

The rule cited most here is 1926.502 (fall protection systems), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Storagexpress Corp. averages $875 across 1 cited inspection.

Storagexpress Corp.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Storagexpress Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344946041 OPENED SEP 16, 2020Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Aug 25, 2021

7618 Marlboro Pike, District Heights, MD 20747 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$875$875Dec 3, 2020Final
Citation 1, item 1b
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0Dec 3, 2020Final
Citation 1, item 1c
29 CFR 1926.502(b)(9) · Fall protection systems
Serious$0$0Dec 3, 2020Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Dec 3, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(1)

(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.

29 CFR 1926.502(b)(2)

(2) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high.

29 CFR 1926.502(b)(9)

(9) Top rails and midrails shall be at least one-quarter inch (0.6 cm) nominal diameter or thickness to prevent cuts and lacerations. If wire rope is used for top rails, it shall be flagged at not more than 6-foot (1.8 m) intervals with high-visibility material.

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Maryland

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.