OSHA SearchOSHA records by employer

Stover & Sons Contractors, Inc.: OSHA inspections and violations

Nashville, Tennessee · Drywall and Insulation Contractors · NAICS 238310

20inspections
59citation items
$32,695current penalties
Aug 11, 2020last inspection

Since 1989, OSHA inspectors have visited Stover & Sons Contractors, Inc. in Tennessee 20 times.

The most recent inspection opened on Aug 11, 2020 after a complaint, in Nashville.

In all, OSHA issued 59 citation items: 47 serious, 4 repeat and 8 other-than-serious.

The proposed penalties came to $43,840; today they stand at $32,695, 25% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 44 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Stover & Sons Contractors, Inc. averages $5,400 across 1 cited inspection.

Stover & Sons Contractors, Inc.: OSHA citation items per year, 1989 to 2020
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

323employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Stover & Sons Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344945290 OPENED AUG 11, 2020Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Oct 6, 2020

315 Interstate Drive, Nashville, TN 37213 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344853403 OPENED JUN 23, 2020Open

Unprogrammed related · Partial · Safety · 8 employees at the site · Open

315 Interstate Drive, Nashville, TN 37213 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,400$5,400Sep 9, 2020Final

Inspection 316511120 OPENED APR 18, 2012Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 15, 2014

7238 Nolensville Road, Nolensville, TN 37135 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315749911 OPENED JUN 17, 2011Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 12, 2014

2705 Memorial Blvd, Springfield, TN 37172 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$800$800Aug 8, 2011Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$800$800Aug 8, 2011Closed
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$800$800Aug 8, 2011Closed
Citation 1, item 4
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,200$1,200Aug 8, 2011Closed
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Aug 8, 2011Closed
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Aug 8, 2011Closed

Inspection 315433318 OPENED FEB 17, 2011Closed

Programmed other · Partial · Safety · 9 employees at the site · Closed May 18, 2011

820 North Thompson Lane, Murfreesboro, TN 37130 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$700$630Mar 30, 2011Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$600$540Mar 30, 2011Closed
Citation 1, item 3
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$600$540Mar 30, 2011Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$700$630Mar 30, 2011Closed
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$600$540Mar 30, 2011Closed

Inspection 311144133 OPENED JUN 5, 2007Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 21, 2007

719 Rivergate Pkwy, Goodlettsville, TN 37072 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$800$800Aug 3, 2007Closed
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$1,600Aug 3, 2007Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 3, 2007Closed
Citation 1, item 2c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 3, 2007Closed
Citation 1, item 3a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$1,600$1,600Aug 3, 2007Closed
Citation 1, item 3b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Aug 3, 2007Closed
Citation 1, item 4a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,600$1,600Aug 3, 2007Closed
Citation 1, item 4b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 3, 2007Closed

Inspection 309227221 OPENED AUG 25, 2005Closed

Planned · Partial · Safety · 11 employees at the site · Closed Nov 15, 2005

2070 Gallatin Pike North, Madison, TN 37115 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$750Oct 17, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Oct 17, 2005Closed
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Oct 17, 2005Closed
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$750$750Oct 17, 2005Closed

Inspection 308197235 OPENED FEB 11, 2005Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 13, 2005

211 Leonard Avenue, Nashville, TN 37205 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

12 older inspections

Inspection 308188911 OPENED SEP 24, 2004Closed

Planned · Complete · Safety · 7 employees at the site · Closed Dec 17, 2004

9101 Carothers Parkway, Franklin, TN 37064 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$1,600$1,600Oct 27, 2004Closed
Citation 1, item 1b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Oct 27, 2004Closed
Citation 1, item 2a
29 CFR 1926.451(e)(2)(ii) · Scaffolds, general requirements
Serious$1,200$1,200Oct 27, 2004Closed
Citation 1, item 2b
29 CFR 1926.451(e)(2)(iv) · Scaffolds, general requirements
Serious$0$0Oct 27, 2004Closed

Inspection 307678771 OPENED JUN 24, 2004Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Jun 29, 2004

18th & Broadway, Nashville, TN 37203 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306776527 OPENED JUL 30, 2003Closed

Planned · Complete · Safety · 10 employees at the site · Closed Nov 6, 2003

1200 Lakeview Court, Franklin, TN 37067 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,050$1,050Sep 16, 2003Closed
Citation 2, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$150$150Sep 16, 2003Closed
Citation 2, item 1b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Sep 16, 2003Closed

Inspection 305600835 OPENED AUG 14, 2002Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 1, 2003

2318 Gallatin Road, Nashville, TN 37172 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$500$500Sep 5, 2002Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$500$500Sep 5, 2002Closed

Inspection 304497175 OPENED JUL 31, 2001Closed

Planned · Partial · Health · 4 employees at the site · Closed Oct 25, 2001

Jackson Square (kroger Shopping Center), Cookeville, TN 38501 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,200$600Aug 28, 2001Closed
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Repeat$3,200$3,200Aug 28, 2001Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$0$0Aug 28, 2001Closed
Citation 1, item 2c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$0$0Aug 28, 2001Closed

Inspection 304001092 OPENED DEC 1, 2000Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 22, 2001

9101 Carothers Parkway, Franklin, TN 37064 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$700$700Jan 23, 2001Closed
Citation 1, item 1b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Jan 23, 2001Closed
Citation 1, item 1c
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Jan 23, 2001Closed
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 23, 2001Closed
Citation 1, item 1e
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jan 23, 2001Closed
Citation 1, item 1f
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Jan 23, 2001Closed

Inspection 114477896 OPENED AUG 11, 1994Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 15, 1995

2100 Nashville Pike, Gallatin, TN 37066 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,000$200Sep 2, 1994Closed
Citation 1, item 2
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$3,500$350Sep 2, 1994Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$3,500$350Sep 2, 1994Closed
Citation 2, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$1,250$250Sep 2, 1994Closed
Citation 2, item 2
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Serious$1,250$125Sep 2, 1994Closed

Inspection 114473143 OPENED SEP 29, 1993Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 27, 1994

7104 Hwy. 70 South, Nashville, TN 37221 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$150$150Oct 27, 1993Closed
Citation 1, item 2
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$300$300Oct 27, 1993Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$350$350Oct 27, 1993Closed

Inspection 114510837 OPENED APR 8, 1992Closed

Planned · Complete · Safety · 30 employees at the site · Closed Jan 21, 1994

Hwy. 100, Lyles, TN 37098 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$400$400Apr 17, 1992Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Apr 17, 1992Closed
Citation 2, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Other-than-serious$0$0Apr 17, 1992Closed

Inspection 107890873 OPENED NOV 19, 1989Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 23, 1990

10th & Clifton Avenue, Nashville, TN 37208 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$120$120Nov 29, 1989Closed

Inspection 107876492 OPENED SEP 21, 1989Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 14, 1990

9101 Carothers Parkway, Franklin, TN 37064 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Repeat$1,200$1,200Oct 3, 1989Closed

Inspection 107906869 OPENED MAY 12, 1989Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 22, 1989

21st & Patterson Street, Nashville, TN 37203 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$420$420May 19, 1989Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0May 19, 1989Closed
Citation 2, item 2
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0May 19, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.59 · Hazard communication

Other drywall and insulation contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.