OSHA SearchOSHA records by employer

Strategic Environmental Response Solutions, LLC.: OSHA inspections and violations

Rumford, Maine · Remediation Services · NAICS 562910

1inspections
15citation items
$29,791current penalties
Jun 2, 2025last inspection

Strategic Environmental Response Solutions, LLC. has one OSHA inspection on record in Maine.

OSHA opened it on Jun 2, 2025 on a referral, in Rumford.

From that inspection OSHA issued 15 citation items: 13 serious and 2 other-than-serious.

OSHA proposed $51,306 in penalties. After settlements and reviews the total is $29,791, down 42%.

Most often, OSHA cited 1910.146, permit-required confined spaces (12 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,218. Strategic Environmental Response Solutions, LLC. averages $29,791 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Strategic Environmental Response Solutions, LLC.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Strategic Environmental Response Solutions, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348277765 OPENED JUN 2, 2025Closed

Referral · Partial · Safety · 8 employees at the site · Closed Jan 14, 2026

35 Hartford Street, Rumford, ME 04276 · Remediation Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Other-than-serious$11,585$0Sep 17, 2025Final
Citation 1, item 1b
29 CFR 1910.29(b)(6) · Fall protection systems in general industry
Other-than-serious$0$0Sep 17, 2025Final
Citation 1, item 2
29 CFR 1910.30(a)(3)(i) · Training requirements
Serious$9,847$7,385Sep 17, 2025Final
Citation 1, item 3a
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$11,585$8,689Sep 17, 2025Final
Citation 1, item 3b
29 CFR 1910.146(f)(2) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 3c
29 CFR 1910.146(f)(5) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 3d
29 CFR 1910.146(f)(6) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 3e
29 CFR 1910.146(f)(7) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 3f
29 CFR 1910.146(f)(10) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 4
29 CFR 1910.146(h)(3) · Permit-required confined spaces
Serious$7,035$5,276Sep 17, 2025Final
Citation 1, item 5a
29 CFR 1910.146(j)(2) · Permit-required confined spaces
Serious$5,627$4,220Sep 17, 2025Final
Citation 1, item 5b
29 CFR 1910.146(i)(1) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 5c
29 CFR 1910.146(i)(5) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final
Citation 1, item 6a
29 CFR 1910.146(k)(3)(i) · Permit-required confined spaces
Serious$5,627$4,220Sep 17, 2025Final
Citation 1, item 6b
29 CFR 1910.146(k)(3)(ii) · Permit-required confined spaces
Serious$0$0Sep 17, 2025Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 28, 2025, Rumford: Hospitalization · injuries to the brain, spinal cord and severe wounds, internal injuries · head and trunk

A contractor employee was washing down an evaporator unit when they fell approximately 87 feet from a scaffold. The employee sustained fractures to their spine, collarbone and ribs, as well as injuries to their brain, lungs, and kidneys.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(f)(10)

(10) The results of initial and periodic tests performed under paragraph (d)(5) of this section, accompanied by the names or initials of the testers and by an indication of when the tests were performed;

29 CFR 1910.146(f)(2)

(2) The purpose of the entry;

29 CFR 1910.146(f)(5)

(5) The personnel, by name, currently serving as attendants;

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.30 · Training requirements

Other remediation services employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.