OSHA SearchOSHA records by employer

Strategic Pharmaceutical Solutions Inc: OSHA inspections and violations

Portland, Oregon · Drugs and Druggists' Sundries Merchant Wholesalers · NAICS 424210

4inspections
3citation items
$180current penalties
Sep 18, 2017last inspection

Strategic Pharmaceutical Solutions Inc has 4 OSHA inspections on record in Oregon, the first in 2009.

OSHA's last visit started on Sep 18, 2017 after a complaint, in Portland.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $180 in penalties and the amount has not been reduced.

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,424. Strategic Pharmaceutical Solutions Inc averages $0 over 1 cited inspection in that time.

Strategic Pharmaceutical Solutions Inc also files yearly injury logs with OSHA, summarized below.

Strategic Pharmaceutical Solutions Inc: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

396employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Strategic Pharmaceutical Solutions Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342643731 OPENED SEP 18, 2017Closed

Complaint · Partial · Safety · 150 employees at the site · Closed Feb 1, 2018

17014 Ne Sandy Blvd, Portland, OR 97230 · Drugs and Druggists' Sundries Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(4)-9
Other-than-serious$0$0Oct 12, 2017Final

Inspection 317696656 OPENED APR 15, 2014Closed

Complaint · Partial · Safety · 68 employees at the site · Closed Apr 16, 2014

17014 Ne Sandy Blvd, Portland, OR 97230 · Drugs and Druggists' Sundries Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312841935 OPENED MAR 17, 2009Closed

Referral · Partial · Health · 35 employees at the site · Closed Apr 3, 2009

17014 Ne Sandy Blvd, Portland, OR 97230 · Drugs and Druggists' Sundries Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312841836 OPENED MAR 5, 2009Closed

Planned · Complete · Safety · 35 employees at the site · Closed Jun 29, 2009

17014 Ne Sandy Blvd, Portland, OR 97230 · Veterinary Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$180$180Mar 26, 2009Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 26, 2009Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Portland site logged 1 recordable injury or illness among about 150 workers: 0.6 per 100 full-time workers, against a median of 1.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Vetsource Oregon
Portland · 2021
150 100.61.5

Included with any plan: 2 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

Other drugs and druggists' sundries merchant wholesalers employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.