OSHA SearchOSHA records by employer

Stratford Homes Limited Partnership: OSHA inspections and violations

Stratford, Wisconsin · Prefabricated Wood Building Manufacturing · NAICS 321992

4inspections
10citation items
$36,524current penalties
Jul 13, 2026last inspection

OSHA has inspected Stratford Homes Limited Partnership 4 times in Wisconsin since 2014.

The latest one began on Jul 13, 2026 after a complaint, in Stratford.

Those inspections ended with 10 citation items: 8 serious and 2 other-than-serious.

Penalties were first proposed at $65,515 and now stand at $36,524, 44% lower after settlements or reviews.

Electrical equipment, general requirements comes up most often in these citations: 3 items under 1910.303.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Stratford Homes Limited Partnership averages $16,388 (2 cited inspections).

Stratford Homes Limited Partnership also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Stratford Homes Limited Partnership: OSHA citation items per year, 2014 to 2026
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Stratford Homes Limited Partnership and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349049072 OPENED JUL 13, 2026Closed

Complaint · Partial · Safety · 110 employees at the site · Closed Oct 30, 2026

212501 State Highway 97, Stratford, WI 54484 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$12,769$4,000Sep 30, 2026Final
Citation 2, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$20,427$12,600Sep 30, 2026Final
Citation 3, item 1
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Other-than-serious$0$0Sep 30, 2026Final

Inspection 347760142 OPENED SEP 17, 2024Closed

Complaint · Partial · Safety · 110 employees at the site · Closed Apr 25, 2025

212501 State Highway 97, Stratford, WI 54484 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$8,296$4,977Nov 8, 2024Final
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$8,296$4,977Nov 8, 2024Final
Citation 1, item 2b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Nov 8, 2024Final
Citation 1, item 3a
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$10,372$6,222Nov 8, 2024Final
Citation 1, item 3b
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Nov 8, 2024Final

Inspection 344572185 OPENED JAN 22, 2020Closed

Referral · Partial · Safety · 96 employees at the site · Closed Feb 3, 2020

212501 State Highway 97 P.o. Box 37, Stratford, WI 54484 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 14, 2020: Employee falls from elevated platform and breaks leg

At 7:15 a.m. on January 14, 2020, an employee was working on a wall section that had been laid flat on a work table. The employee was building a section of the wall on one of the many 31-inch tall worktables within the production area. Wall sections are laid flat onto these tables so that employees are working at waist height. The employee was stapling Oriented Strand Board (OSB) onto the wall sections with a pneumatic staple gun. The employee had accessed the work platform using a ladder and was kneeling as she stapled the OSB into place. The employee fell from the table and broke her tibia and fibula of the right leg. The employee was hospitalized.

No citations from this inspection.

Inspection 339745952 OPENED APR 28, 2014Closed

Planned · Records only · Safety · 74 employees at the site · Closed May 20, 2014

402 S Weber Avenue, Stratford, WI 54484 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$2,975$2,082May 5, 2014Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,380$1,666May 5, 2014Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Stratford site logged 18 recordable injuries or illnesses among about 108 workers: 19.2 per 100 full-time workers, against a median of 4.6 for its industry. Those cases cost 20 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Stratford Homes Limited Partnership
Stratford · 2025
108 18719.24.6

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 9, 2025, Stratford: Hospitalization · infections of the skin and subcutaneous tissue unspecified · knee(s)

An employee was working on flooring tile, which required several continuous hours of kneeling. The next morning, he noticed fluid and swelling on the right knee. When he knelt to perform work tasks, he felt an immediate sharp, burning pain. The employee was hospitalized with an infection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(a)(9)

(9) All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of § 1910.219.

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(3)

(3) Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment