OSHA SearchOSHA records by employer

Structural 0201, LLC: OSHA inspections and violations

Trinity, North Carolina · Truss Manufacturing · NAICS 321214

1inspections
3citation items
$9,200current penalties
Mar 11, 2025last inspection

OSHA inspectors have visited Structural 0201, LLC in North Carolina one time.

It opened on Mar 11, 2025 after a complaint, in Trinity.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $13,200; today they stand at $9,200, 30% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Structural 0201, LLC averages $9,200 across 1 cited inspection.

Structural 0201, LLC also files yearly injury logs with OSHA, summarized below.

Structural 0201, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Structural 0201, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348105784 OPENED MAR 11, 2025Closed

Complaint · Partial · Health · 40 employees at the site · Closed Aug 19, 2025

300 Roelee St, Trinity, NC 27370 · Truss Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(b) · Machine guarding
Serious$5,200$4,200Jul 2, 2025Final
Citation 1, item 2
29 CFR 1910.252(a)(2)(v) · Welding fire safety
Serious$8,000$5,000Jul 2, 2025Final
Citation 2, item 1
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 2, 2025Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Trinity site logged 7 recordable injuries or illnesses among about 76 workers: 9.8 per 100 full-time workers, against a median of 3.9 for its industry. Those cases cost 67 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Structural 0201, LLC
Trinity · 2025
76 739.83.9

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(1)

(g) Training and education. (1) Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.252(a)(2)(v)

(v) Floors. Where combustible materials such as paper clippings, wood shavings, or textile fibers are on the floor, the floor shall be swept clean for a radius of 35 feet (10.7 m). Combustible floors shall be kept wet, covered with damp sand, or protected by fire-resistant shields. Where floors have been wet down, personnel operating arc welding or cutting equipment shall be protected from possible shock.

Other truss manufacturing employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.